Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2006 Jan;36(1):16-21.
doi: 10.1007/s00247-005-0013-1. Epub 2005 Oct 21.

Volumetric localization of epileptic activities in tuberous sclerosis using synthetic aperture magnetometry

Affiliations

Volumetric localization of epileptic activities in tuberous sclerosis using synthetic aperture magnetometry

Zheng Xiao et al. Pediatr Radiol. 2006 Jan.

Abstract

Background: Magnetoencephalography (MEG) is a novel noninvasive technique for localizing epileptic zones. Tuberous sclerosis complex (TSC) is often associated with medically refractory epilepsy with multiple epileptic zones. Surgical treatment of TSC requires accurate localization of epileptogenic tubers.

Objective: The objective of this study was to introduce a new MEG technique, synthetic aperture magnetometry (SAM), to volumetrically localize irritable zones and clarify the correlations between SAM, dipole modeling and anatomical tubers.

Materials and methods: Eight pediatric patients with TSC confirmed by clinical and neuroimaging findings were retrospectively studied. MEG data were recorded using a whole-cortex CTF OMEGA system. Sleep deprivation was employed to provoke epileptiform activity. Irritable zones were localized using both dipole modeling and SAM.

Results: MRI detected 42 tubers in the eight patients. Dipole modeling localized 28 irritable zones, and 19 out of the 28 zones were near tubers (19/42, 45%). SAM found 51 irritable zones, and 31 out of the 51 zones were near tubers (31/42, 74%). Among the 51 irritable zones determined by SAM, thirty-five zones were in 1-35 Hz, nine zones were in 35-60 Hz, and seven zones were in 60-120 Hz.

Conclusions: The new method, SAM, yielded very plausible equivalent sources for patients who showed anatomical tubers on MRI. Compared to conventional dipole modeling, SAM appeared to offer increased detection of irritable zones and beneficial volumetric and frequency descriptions.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Epilepsia. 2005 Jan;46(1):59-68 - PubMed
    1. Arq Neuropsiquiatr. 2004 Mar;62(1):9-14 - PubMed
    1. Mayo Clin Proc. 1989 Mar;64(3):305-11 - PubMed
    1. J Child Neurol. 2002 Sep;17(9):689-92 - PubMed
    1. Epilepsy Behav. 2004 Jun;5(3):277-85 - PubMed

Publication types