Detection of circulating anodic antigen before and after specific chemotherapy in experimental murine Schistosomiasis mansoni
- PMID: 1624216
- DOI: 10.1016/0192-0561(92)90025-g
Detection of circulating anodic antigen before and after specific chemotherapy in experimental murine Schistosomiasis mansoni
Abstract
In two groups of mice infected with 60 (group I) and 120 (group II) Schistosoma mansoni cercariae, respectively, the effects of intensity and duration of infection, and of praziquantel therapy (curative vs subcurative dose) on the levels of circulating anodic antigen (CAA), were studied. CAA was measured in trichloracetic acid-treated serum samples with an avidin-biotin enzyme-linked immunosorbent assay (AB-ELISA) using the monoclonal anti-CAA antibody. Total worm burdens, oogram patterns and ova counts/g liver and intestine were followed up. The lowest detectable level of CAA was about 1.0 ng/ml, and was positive with a worm load of 3-5/mouse. CAA levels became already detectable as early as 1-2 weeks post-infection (pi) before any parasitological parameter and showed a significant drop from the 11th-12th week pi onwards. A positive correlation was demonstrated between the CAA level and worm load. Following successful praziquantel therapy, CAA disappeared earlier than any of the other parameters studied.
Similar articles
-
Assessment of cure in schistosomiasis patients after chemotherapy with praziquantel by quantitation of circulating anodic antigen (CAA) in urine.Am J Trop Med Hyg. 1991 Mar;44(3):323-8. doi: 10.4269/ajtmh.1991.44.323. Am J Trop Med Hyg. 1991. PMID: 1903605
-
Epidemiology, immunology and chemotherapy of Schistosoma mansoni infections in a recently exposed community in Senegal.Trop Geogr Med. 1994;46(4 Spec No):209-19. Trop Geogr Med. 1994. PMID: 7825223 Clinical Trial.
-
Mixed Schistosoma haematobium and S. mansoni infection: effect of different treatments on the serum level of circulating anodic antigen (CAA).Acta Trop. 1990 Oct;48(1):25-35. doi: 10.1016/0001-706x(90)90062-5. Acta Trop. 1990. PMID: 1980801 Clinical Trial.
-
Circulating anodic antigen levels in serum before and after chemotherapy with praziquantel in schistosomiasis mansoni.Trans R Soc Trop Med Hyg. 1989 May-Jun;83(3):368-72. doi: 10.1016/0035-9203(89)90507-5. Trans R Soc Trop Med Hyg. 1989. PMID: 2515625 Clinical Trial.
-
UCP-LF and other assay methods for schistosome circulating anodic antigen between 1978 and 2022.Biol Methods Protoc. 2023 Apr 3;8(1):bpad006. doi: 10.1093/biomethods/bpad006. eCollection 2023. Biol Methods Protoc. 2023. PMID: 37197579 Free PMC article. Review.
Cited by
-
Serum levels of circulating anodic antigen and circulating cathodic antigen detected in mice infected with Schistosoma japonicum or S. mansoni.Parasitol Res. 1995;81(5):434-7. doi: 10.1007/BF00931506. Parasitol Res. 1995. PMID: 7501644
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Research Materials
Miscellaneous