Objectives: To comparatively evaluate the shaping efficacies of HERO Shaper rotary instruments and Nitiflex hand files.
Study design: The mesial roots of 40 mandibular molars were used. In 20 teeth, the mesiobuccal canals were instrumented with HERO Shaper and the mesiolingual canals with Nitiflex. In the remaining 20 teeth, the mesiobuccal canals were instrumented with Nitiflex and the mesiolingual canals with HERO Shaper. Pre- and postoperative sections were obtained from the coronal, middle, and apical portions and analyzed. Statistical analysis was performed using the Student t test.
Results: More dentin was removed from the middle portion with HERO Shaper (P < .05). No statistically significant difference was observed in terms of transportation (P>.05). No instrument fracture or deformation was noted.
Conclusions: Both HERO Shaper and Nitiflex can be recommended for clinical practice. Further studies can focus on the comparison of HERO Shaper with other rotary instruments as there is an increasing trend for the utilization of these systems.
Similar articles
-
Shaping ability of two rotary instruments in simulated canals: stainless steel ENDOflash and nickel-titanium HERO Shaper.Int Endod J. 2005 Sep;38(9):637-44. doi: 10.1111/j.1365-2591.2005.00997.x. Int Endod J. 2005. PMID: 16104977
-
Comparative investigation of 2 rotary nickel-titanium instruments: protaper universal versus protaper.Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2009 Jun;107(6):886-92. doi: 10.1016/j.tripleo.2009.01.010. Epub 2009 Apr 22. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2009. PMID: 19386519
-
Evaluation of the root dentine cutting effectiveness of the HERO 642, HERO Apical and HERO Shaper rotary systems.Aust Endod J. 2008 Dec;34(3):94-100. doi: 10.1111/j.1747-4477.2007.00086.x. Aust Endod J. 2008. PMID: 19032642
-
Use of nickel titanium instruments for cleaning and shaping root canal systems.Tex Dent J. 2003 Mar;120(3):262-8. Tex Dent J. 2003. PMID: 12723109 Review.
-
Use of nickel titanium instruments for cleaning and shaping root canal systems.J Tenn Dent Assoc. 2003 Spring;83(2):29-33. J Tenn Dent Assoc. 2003. PMID: 12800616 Review. No abstract available.
Cited by
-
An ex-vivo study on the shaping parameters of two nickel-titanium rotary systems compared with hand instruments.Iran Endod J. 2011 Spring;6(2):74-9. Epub 2011 May 15. Iran Endod J. 2011. PMID: 24778687 Free PMC article.
-
Shaping ability of WaveOne Gold and OneReci by using two apical sizes: a micro-computed tomographic assessment.PeerJ. 2023 Apr 27;11:e15208. doi: 10.7717/peerj.15208. eCollection 2023. PeerJ. 2023. PMID: 37131992 Free PMC article.
-
Assessment of canal walls after biomechanical preparation of root canals instrumented with Protaper Universal rotary system.J Appl Oral Sci. 2009 Nov-Dec;17(6):590-5. doi: 10.1590/s1678-77572009000600010. J Appl Oral Sci. 2009. PMID: 20027432 Free PMC article. Clinical Trial.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources