Abstract
An original setup for analysis of glycated haemoglobin (HbA1c) in blood is reported. The construction employed a combination of the piezoelectric biosensor for glycated haemoglobin and the flow-through photometric sensor for total haemoglobin (Hb). The modification of gold electrodes with 3-aminophenylboronic acid (APBA) as a specific ligand was studied; the chemisorbed conjugate of APBA with a long-chain thiocompound provided the best affinity for HbA1c. The effect of various operating parameters, such as flow rate and instrumental setup, was optimised. The total haemoglobin content was analysed as absorbance of the haemoglobin-cyanide derivative at 540 nm. Only one standard (calibrator) diluted in various ratio was necessary for calibration and 1 microl of blood was sufficient for analysis. The full range of HbA1c content (4-15%) in blood can be analysed; the working ranges of total and glycated haemoglobin were 50-2000 and 10-90 microg/ml, respectively. The developed method was successfully evaluated on blood samples collected from diabetics.
Similar articles
-
A multiplexed three-dimensional paper-based electrochemical impedance device for simultaneous label-free affinity sensing of total and glycated haemoglobin: The potential of using a specific single-frequency value for analysis.Anal Chim Acta. 2016 Sep 14;936:1-11. doi: 10.1016/j.aca.2016.05.047. Epub 2016 Jun 3. Anal Chim Acta. 2016. PMID: 27566337
-
A disposable amperometric dual-sensor for the detection of hemoglobin and glycated hemoglobin in a finger prick blood sample.Biosens Bioelectron. 2017 May 15;91:128-135. doi: 10.1016/j.bios.2016.12.038. Epub 2016 Dec 15. Biosens Bioelectron. 2017. PMID: 28006679
-
Boronate-Modified Interdigitated Electrode Array for Selective Impedance-Based Sensing of Glycated Hemoglobin.Anal Chem. 2016 Oct 4;88(19):9582-9589. doi: 10.1021/acs.analchem.6b02234. Epub 2016 Sep 21. Anal Chem. 2016. PMID: 27598723
-
Analytical techniques for the detection of glycated haemoglobin underlining the sensors.Int J Biol Macromol. 2020 Jul 15;155:685-696. doi: 10.1016/j.ijbiomac.2020.03.205. Epub 2020 Mar 27. Int J Biol Macromol. 2020. PMID: 32229211 Review.
-
Current issues in glycated haemoglobin measurement.Clin Lab. 2001;47(7-8):377-85. Clin Lab. 2001. PMID: 11499800 Review. No abstract available.
Cited by
-
Recent Progress in Electrochemical HbA1c Sensors: A Review.Materials (Basel). 2015 Mar 17;8(3):1187-1203. doi: 10.3390/ma8031187. Materials (Basel). 2015. PMID: 28787996 Free PMC article. Review.
-
Current Status of HbA1c Biosensors.Sensors (Basel). 2017 Aug 4;17(8):1798. doi: 10.3390/s17081798. Sensors (Basel). 2017. PMID: 28777351 Free PMC article. Review.
-
Method and apparatus using selected superparamagnetic labels for rapid quantification of immunochromatographic tests.Nanotechnol Sci Appl. 2009 Apr 14;2:13-20. doi: 10.2147/nsa.s4738. eCollection 2009. Nanotechnol Sci Appl. 2009. PMID: 24198463 Free PMC article.
-
Magnetite-Quantum Dot Immunoarray for Plasmon-Coupled-Fluorescence Imaging of Blood Insulin and Glycated Hemoglobin.ACS Sens. 2017 Jul 28;2(7):909-915. doi: 10.1021/acssensors.7b00124. Epub 2017 Jun 23. ACS Sens. 2017. PMID: 28750536 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical