Corrosion between the components of modular femoral hip prostheses
- PMID: 1624507
- DOI: 10.1302/0301-620X.74B4.1624507
Corrosion between the components of modular femoral hip prostheses
Abstract
We studied the tapered interface between the head and the neck of 139 modular femoral components of hip prostheses which had been removed for a variety of reasons. In 91 the same alloy had been used for the head and the stem; none of them showed evidence of corrosion. In contrast, there was definite corrosion in 25 of the 48 prostheses in which the stem was of titanium alloy and the head of cobalt-chrome. This corrosion was time-dependent: no specimens were corroded after less than nine months in the body, but all which had been in place for more than 40 months were damaged. We discuss the factors which may influence the rate of these changes and present evidence that they were due to galvanically-accelerated crevice corrosion, which was undetected in previous laboratory testing of this type of prosthesis.
Similar articles
-
Modular titanium alloy neck adapter failures in hip replacement--failure mode analysis and influence of implant material.BMC Musculoskelet Disord. 2010 Jan 4;11:3. doi: 10.1186/1471-2474-11-3. BMC Musculoskelet Disord. 2010. PMID: 20047653 Free PMC article.
-
Corrosion at the interface. A possible solution to cobalt-chrome heads on titanium alloy stems.J Arthroplasty. 1996 Feb;11(2):157-62. doi: 10.1016/s0883-5403(05)80010-5. J Arthroplasty. 1996. PMID: 8648309
-
Trunnion Failure of the Recalled Low Friction Ion Treatment Cobalt Chromium Alloy Femoral Head.J Arthroplasty. 2017 Sep;32(9):2857-2863. doi: 10.1016/j.arth.2017.03.075. Epub 2017 Apr 8. J Arthroplasty. 2017. PMID: 28478184 Free PMC article.
-
Corrosion at the head-neck interface of current designs of modular femoral components: essential questions and answers relating to corrosion in modular head-neck junctions.Bone Joint J. 2016 May;98-B(5):579-84. doi: 10.1302/0301-620X.98B5.35592. Bone Joint J. 2016. PMID: 27143725 Review.
-
Surface topography, corrosion and microhardness of nitrogen-diffusion-hardened titanium alloy.Biomaterials. 1999 Sep;20(18):1709-16. doi: 10.1016/s0142-9612(99)00079-4. Biomaterials. 1999. PMID: 10503972 Review.
Cited by
-
Corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty.J Bone Joint Surg Am. 2012 Sep 19;94(18):1655-61. doi: 10.2106/jbjs.k.01352. J Bone Joint Surg Am. 2012. PMID: 23289127 Free PMC article.
-
A case of a C-stem fracture at the head-neck junction and a review of the literature.Case Rep Orthop. 2012;2012:158604. doi: 10.1155/2012/158604. Epub 2012 Dec 9. Case Rep Orthop. 2012. PMID: 23304589 Free PMC article.
-
In Vivo Damage of the Head-Neck Junction in Hard-on-Hard Total Hip Replacements: Effect of Femoral Head Size, Metal Combination, and 12/14 Taper Design.Materials (Basel). 2017 Jul 1;10(7):733. doi: 10.3390/ma10070733. Materials (Basel). 2017. PMID: 28773095 Free PMC article.
-
Comparison of ceramic-on-ceramic bearing vs ceramic-on-highly cross-linked polyethylene-bearing surfaces in total hip arthroplasty for avascular necrosis of femoral head: a prospective cohort study with a mid-term follow-up.J Orthop Surg Res. 2019 Nov 27;14(1):388. doi: 10.1186/s13018-019-1410-8. J Orthop Surg Res. 2019. PMID: 31775827 Free PMC article.
-
Stem-Sleeve Junction Failure of a Modular Femoral Hip System: a Retrieval Analysis.HSS J. 2015 Oct;11(3):285-90. doi: 10.1007/s11420-015-9455-7. Epub 2015 Jul 9. HSS J. 2015. PMID: 26981063 Free PMC article. No abstract available.
Publication types
MeSH terms
Substances
LinkOut - more resources
Other Literature Sources