Evaluation of the Autoscan Walkaway system for rapid identification and susceptibility testing of gram-negative bacilli
- PMID: 1624575
- PMCID: PMC265330
- DOI: 10.1128/jcm.30.6.1568-1571.1992
Evaluation of the Autoscan Walkaway system for rapid identification and susceptibility testing of gram-negative bacilli
Abstract
We evaluated the performance of the Autoscan Walkaway (W/A) system (MicroScan, Sacramento, Calif.) in conjunction with the fluorometric Neg Combo panels for rapid identification and susceptibility testing of gram-negative bacilli. Fermentative and nonfermentative gram-negative bacilli were tested in parallel with the W/A system and the Cathra Repliscan replicator (C/R) system (Cathra, St. Paul, Minn.). Conventional biochemical testing and agar dilution testing were used to resolve the identification and susceptibility testing discrepancies. Of 495 clinical isolates tested, 445 (90%) were correctly identified by the W/A system and 483 (98%) were correctly identified by the C/R system. Repeat testing by using updated versions of the W/A system's computer identification software failed to demonstrate improved identification accuracy. For susceptibility testing, the W/A system demonstrated 5.6% total interpretative category errors, including only 0.9% major and very major errors. The comparative C/R system produced only 1% errors overall, including 0.2% major and very major errors. Although the W/A system is highly automated and is capable of producing results rapidly, our findings suggest that additional identification and susceptibility testing refinements are needed before the system will be suitable for routine use.
Similar articles
-
Comparison of the autoSCAN-W/A rapid bacterial identification system and the Vitek AutoMicrobic system for identification of gram-negative bacilli.J Clin Microbiol. 1991 Jul;29(7):1422-8. doi: 10.1128/jcm.29.7.1422-1428.1991. J Clin Microbiol. 1991. PMID: 1885737 Free PMC article.
-
Rapid antimicrobial susceptibility testing of gram-negative bacilli using Baxter MicroScan rapid fluorogenic panels and autoSCAN-W/A.Pathol Biol (Paris). 1991 May;39(5):461-5. Pathol Biol (Paris). 1991. PMID: 1881675
-
Direct comparison of the BD phoenix system with the MicroScan WalkAway system for identification and antimicrobial susceptibility testing of Enterobacteriaceae and nonfermentative gram-negative organisms.J Clin Microbiol. 2008 Jul;46(7):2327-33. doi: 10.1128/JCM.00075-08. Epub 2008 May 21. J Clin Microbiol. 2008. PMID: 18495856 Free PMC article.
-
Multilaboratory study of the Biomic automated well-reading instrument versus MicroScan WalkAway for reading MicroScan antimicrobial susceptibility and identification panels.J Clin Microbiol. 2013 May;51(5):1548-54. doi: 10.1128/JCM.03088-12. Epub 2013 Mar 13. J Clin Microbiol. 2013. PMID: 23486713 Free PMC article.
-
The Evolving Role of the Clinical Microbiology Laboratory in Identifying Resistance in Gram-Negative Bacteria: An Update.Infect Dis Clin North Am. 2020 Dec;34(4):659-676. doi: 10.1016/j.idc.2020.08.001. Epub 2020 Sep 30. Infect Dis Clin North Am. 2020. PMID: 33011047 Review.
Cited by
-
Comparison of Microdilution Method with Agar Dilution Method for Antibiotic Susceptibility Test of Neisseria gonorrhoeae.Infect Drug Resist. 2020 Jun 15;13:1775-1780. doi: 10.2147/IDR.S253811. eCollection 2020. Infect Drug Resist. 2020. PMID: 32606827 Free PMC article.
-
Particular biochemical profiles for enterohemorrhagic Escherichia coli O157:H7 isolates on the ID 32E system.J Clin Microbiol. 2001 Mar;39(3):1161-4. doi: 10.1128/JCM.39.3.1161-1164.2001. J Clin Microbiol. 2001. PMID: 11230449 Free PMC article.
-
Identification of Hafnia alvei with the MicroScan WalkAway system.J Clin Microbiol. 1999 Dec;37(12):4186-8. doi: 10.1128/JCM.37.12.4186-4188.1999. J Clin Microbiol. 1999. PMID: 10565961 Free PMC article.
-
A new rapid resazurin-based microdilution assay for antimicrobial susceptibility testing of Neisseria gonorrhoeae.J Antimicrob Chemother. 2017 Jul 1;72(7):1961-1968. doi: 10.1093/jac/dkx113. J Antimicrob Chemother. 2017. PMID: 28431096 Free PMC article.
-
Evaluation of the VITEK 2 system for the identification and susceptibility testing of three species of nonfermenting gram-negative rods frequently isolated from clinical samples.J Clin Microbiol. 2001 Sep;39(9):3247-53. doi: 10.1128/JCM.39.9.3247-3253.2001. J Clin Microbiol. 2001. PMID: 11526158 Free PMC article.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources