CT radiation dose and image quality
- PMID: 16253656
- DOI: 10.1016/j.rcl.2005.07.002
CT radiation dose and image quality
Abstract
Image quality is proportional to radiation dose. Improvements in image quality come at a cost of increased radiation dose. CT scanners are more robust today than even 5 years ago. X-ray tubes are capable of producing high levels of almost continuous radiation for rapid CT volume acquisitions and angiographic studies. All parameters of modern CT scanners provide rapid subsecond, large-volume CT acquisitions. How high we go needs to be tempered by how high we should go regarding radiation dose from CT examinations. Radiologists, referring physicians, medical physicists, CT technologists, CT equipment manufacturers, and regulators need to evaluate the appropriateness of radiation dose for different CT studies.
Similar articles
-
Quality assurance in CT.Radiol Technol. 2000 Sep-Oct;72(1):67. Radiol Technol. 2000. PMID: 11019412 No abstract available.
-
Automatic exposure control in computed tomography--an evaluation of systems from different manufacturers.Acta Radiol. 2010 Jul;51(6):625-34. doi: 10.3109/02841851003698206. Acta Radiol. 2010. PMID: 20429764
-
Importance in optimization of multi-slice computed tomography scan protocols.Australas Radiol. 2006 Jun;50(3):278-85. doi: 10.1111/j.1440-1673.2006.01579.x. Australas Radiol. 2006. PMID: 16732832 Review.
-
Image quality and patient dose in computed tomography examinations in Greece.Radiat Prot Dosimetry. 2011 Sep;147(1-2):129-32. doi: 10.1093/rpd/ncr282. Epub 2011 Jul 9. Radiat Prot Dosimetry. 2011. PMID: 21743078
-
Minimizing radiation dose for coronary CT angiography.Cardiol Clin. 2012 Feb;30(1):9-17. doi: 10.1016/j.ccl.2011.11.003. Epub 2011 Dec 2. Cardiol Clin. 2012. PMID: 22304946 Review.
Cited by
-
Comparison of digital tomosynthesis and chest radiography for the detection of pulmonary nodules: systematic review and meta-analysis.Br J Radiol. 2016 Dec;89(1068):20160421. doi: 10.1259/bjr.20160421. Epub 2016 Oct 19. Br J Radiol. 2016. PMID: 27759428 Free PMC article.
-
Fast and low-dose medical imaging generation empowered by hybrid deep-learning and iterative reconstruction.Cell Rep Med. 2023 Jul 18;4(7):101119. doi: 10.1016/j.xcrm.2023.101119. Cell Rep Med. 2023. PMID: 37467726 Free PMC article.
-
Thyroid Radiation Dose to Patients from Diagnostic Radiology Procedures over Eight Decades: 1930-2010.Health Phys. 2017 Dec;113(6):458-473. doi: 10.1097/HP.0000000000000723. Health Phys. 2017. PMID: 28968349 Free PMC article.
-
Real practice radiation dose and dosimetric impact of radiological staff training in body CT examinations.Insights Imaging. 2013 Apr;4(2):239-44. doi: 10.1007/s13244-013-0241-0. Epub 2013 Mar 15. Insights Imaging. 2013. PMID: 23494878 Free PMC article.
-
A comparison of digital tomosynthesis and chest radiography in evaluating airway lesions using computed tomography as a reference.Eur Radiol. 2016 Sep;26(9):3147-54. doi: 10.1007/s00330-015-4127-z. Epub 2015 Dec 11. Eur Radiol. 2016. PMID: 26662264
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical