Repeat CT imaging and replanning during the course of IMRT for head-and-neck cancer
- PMID: 16256277
- DOI: 10.1016/j.ijrobp.2005.07.957
Repeat CT imaging and replanning during the course of IMRT for head-and-neck cancer
Abstract
Purpose: Many patients with head-and-neck (H&N) cancer have tumor shrinkage and/or weight loss during the course of radiotherapy. We conducted this retrospective study to determine the dosimetric effects of repeat computed tomography (CT) imaging and replanning during the course of intensity-modulated radiotherapy (IMRT) on both normal tissues and target volumes.
Methods and materials: A retrospective chart review identified 13 patients with H&N cancer treated with IMRT who had repeat CT imaging and replanning during the course of radiotherapy. The first IMRT plan for each patient was generated based on the original planning CT scan acquired before the start of treatment. Because of tumor shrinkage or weight loss during radiotherapy, a second CT scan was acquired, and a new plan was generated and used to complete the course of IMRT. CT-CT fusion was used to correct patient positioning differences between the scans. By using a commercial inverse IMRT planning system, a hybrid IMRT plan was generated for each patient by applying the beam configurations of the first IMRT plan (including the intensity profile of each beam) to the anatomy of the second CT scan. The dose-volume histograms of the actual and hybrid IMRT plans were compared using analysis of variance methods for repeated measures.
Results: All patients had locally advanced, nonmetastatic Stage III or IV disease, including 6 nasopharynx, 6 oropharynx, and 1 unknown primary site. All patients were treated with concurrent platinum-based chemotherapy. When replanning vs. not replanning was compared, the hybrid IMRT plans (without replanning) demonstrated reduced doses to target volumes and increased doses to critical structures. The doses to 95% (D95) of the planning target volumes of the gross tumor volume (PTVGTV) and the clinical target volume (PTVCTV) were reduced in 92% of patients, by 0.8-6.3 Gy (p=0.02) and 0.2-7.4 Gy (p=0.003), respectively. The maximum dose (Dmax) to the spinal cord increased in all patients (range, 0.2-15.4 Gy; p=0.003) and the brainstem Dmax increased in 85% of patients without replanning (range, 0.6-8.1 Gy; p=0.007).
Conclusions: Repeat CT imaging and replanning during the course of IMRT for selected patients with H&N cancer is essential to identify dosimetric changes and to ensure adequate doses to target volumes and safe doses to normal tissues. Future prospective studies with larger sample sizes will help to determine criteria for repeat CT imaging and IMRT replanning for H&N cancer patients undergoing radiotherapy.
Similar articles
-
Relative plan robustness of step-and-shoot vs rotational intensity-modulated radiotherapy on repeat computed tomographic simulation for weight loss in head and neck cancer.Med Dosim. 2016 Summer;41(2):154-8. doi: 10.1016/j.meddos.2016.01.001. Epub 2016 Mar 15. Med Dosim. 2016. PMID: 26993081
-
Clinical study of the necessity of replanning before the 25th fraction during the course of intensity-modulated radiotherapy for patients with nasopharyngeal carcinoma.Int J Radiat Oncol Biol Phys. 2010 Jun 1;77(2):617-21. doi: 10.1016/j.ijrobp.2009.08.036. Epub 2010 Feb 6. Int J Radiat Oncol Biol Phys. 2010. PMID: 20138444
-
Monitoring dosimetric impact of weight loss with kilovoltage (kV) cone beam CT (CBCT) during parotid-sparing IMRT and concurrent chemotherapy.Int J Radiat Oncol Biol Phys. 2012 Mar 1;82(3):e375-82. doi: 10.1016/j.ijrobp.2011.07.004. Epub 2011 Dec 22. Int J Radiat Oncol Biol Phys. 2012. PMID: 22197229
-
Adaptive radiotherapy of head and neck cancer.Semin Radiat Oncol. 2010 Apr;20(2):84-93. doi: 10.1016/j.semradonc.2009.11.002. Semin Radiat Oncol. 2010. PMID: 20219546 Review.
-
[Target volume delineation for head and neck cancer intensity-modulated radiotherapy].Cancer Radiother. 2011 Oct;15(6-7):466-72. doi: 10.1016/j.canrad.2011.07.239. Epub 2011 Aug 30. Cancer Radiother. 2011. PMID: 21880533 Review. French.
Cited by
-
Impact of head and neck cancer adaptive radiotherapy to spare the parotid glands and decrease the risk of xerostomia.Radiat Oncol. 2015 Jan 9;10:6. doi: 10.1186/s13014-014-0318-z. Radiat Oncol. 2015. PMID: 25573091 Free PMC article.
-
Analysis of patient-specific quality assurance for Elekta Unity adaptive plans using statistical process control methodology.J Appl Clin Med Phys. 2021 Apr;22(4):99-107. doi: 10.1002/acm2.13219. Epub 2021 Mar 23. J Appl Clin Med Phys. 2021. PMID: 33756059 Free PMC article.
-
Impact of residual setup error on parotid gland dose in intensity-modulated radiation therapy with or without planning organ-at-risk margin.Strahlenther Onkol. 2009 Jul;185(7):453-9. doi: 10.1007/s00066-009-1888-9. Epub 2009 Aug 28. Strahlenther Onkol. 2009. PMID: 19714307
-
CT-on-Rails Versus In-Room CBCT for Online Daily Adaptive Proton Therapy of Head-and-Neck Cancers.Cancers (Basel). 2021 Nov 28;13(23):5991. doi: 10.3390/cancers13235991. Cancers (Basel). 2021. PMID: 34885100 Free PMC article.
-
Deterioration of Intended Target Volume Radiation Dose Due to Anatomical Changes in Patients with Head-and-Neck Cancer.Cancers (Basel). 2021 Aug 24;13(17):4253. doi: 10.3390/cancers13174253. Cancers (Basel). 2021. PMID: 34503061 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical