Estimation of maximal oxygen uptake by bioelectrical impedance analysis
- PMID: 16261389
- DOI: 10.1007/s00421-005-0025-4
Estimation of maximal oxygen uptake by bioelectrical impedance analysis
Abstract
Previous non-exercise models for the prediction of maximal oxygen uptake VO(2max) have failed to accurately discriminate cardiorespiratory fitness within large cohorts. The aim of the present study was to evaluate the feasibility of a completely indirect method for predicting VO(2max) that was based on bioelectrical impedance analysis (BIA) in 66 young, healthy fit men and women. Multiple, stepwise regression analysis was used to determine the usefulness of BIA and additional covariates to estimate VO(2max) (ml min(-1)). BIA was highly correlated to VO(2max) (r = 0.914; P < 0.001) and entered the regression equation first. The inclusion of gender and a physical activity rating further improved the model which accounted for 88% of the variance in VO(2max) and resulted in a relative standard error of the estimate (SEE) of 7.2%. Substantial agreement between the methods was confirmed by the fact that nearly all the differences were within +/-2 SD. Furthermore, in contrast to previously published non-exercise models, no trend of a reduction in prediction accuracy with increasing VO(2max) values was apparent. It was concluded that a non-exercise model based on BIA might be a rapid and useful technique to estimate VO(2max), when a direct test does not seem feasible. However, though the present results are useful to determine the viability of the method, further refinement of the BIA approach and its validation in a large, diverse population is needed before it can be applied to the clinical and epidemiological settings.
Similar articles
-
Prediction of maximal oxygen uptake by bioelectrical impedance analysis in overweight adolescents.J Sports Med Phys Fitness. 2009 Sep;49(3):240-5. J Sports Med Phys Fitness. 2009. PMID: 19861930 Free PMC article.
-
VO(2max) prediction from multi-frequency bioelectrical impedance analysis.Physiol Meas. 2008 Feb;29(2):193-203. doi: 10.1088/0967-3334/29/2/003. Epub 2008 Jan 14. Physiol Meas. 2008. PMID: 18256451
-
Comparison of estimated and measured maximal oxygen uptake during exercise testing in patients with chronic obstructive pulmonary disease.Intern Med J. 2004 Aug;34(8):469-74. doi: 10.1111/j.1445-5994.2004.00651.x. Intern Med J. 2004. PMID: 15317545
-
Estimation of maximal oxygen uptake via submaximal exercise testing in sports, clinical, and home settings.Sports Med. 2013 Sep;43(9):865-73. doi: 10.1007/s40279-013-0068-3. Sports Med. 2013. PMID: 23821468 Review.
-
Methodological and practical application issues in exercise prescription using the heart rate reserve and oxygen uptake reserve methods.J Sci Med Sport. 2011 Jan;14(1):46-57. doi: 10.1016/j.jsams.2010.07.008. Epub 2010 Sep 15. J Sci Med Sport. 2011. PMID: 20833587 Review.
Cited by
-
Prediction of maximal oxygen uptake by bioelectrical impedance analysis in overweight adolescents.J Sports Med Phys Fitness. 2009 Sep;49(3):240-5. J Sports Med Phys Fitness. 2009. PMID: 19861930 Free PMC article.
-
Muscle assessment using multi-frequency bioimpedance in a healthy Danish population aged 20-69 years: a powerful non-invasive tool in sports and in the clinic.Physiol Rep. 2019 Jun;7(11):e14109. doi: 10.14814/phy2.14109. Physiol Rep. 2019. PMID: 31197976 Free PMC article.
-
Wearable Multi-Frequency and Multi-Segment Bioelectrical Impedance Spectroscopy for Unobtrusively Tracking Body Fluid Shifts during Physical Activity in Real-Field Applications: A Preliminary Study.Sensors (Basel). 2016 May 11;16(5):673. doi: 10.3390/s16050673. Sensors (Basel). 2016. PMID: 27187389 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous