Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2006 Apr;16(4):889-97.
doi: 10.1007/s0330-005-0032-1. Epub 2005 Nov 3.

Clinical evaluation of bone-subtraction CT angiography (BSCTA) in head and neck imaging

Affiliations

Clinical evaluation of bone-subtraction CT angiography (BSCTA) in head and neck imaging

M Lell et al. Eur Radiol. 2006 Apr.

Abstract

Fifty-one patients were examined with bone subtraction CT angiography (BSCTA). Data were acquired on 4-and 64-slice spiral CT systems. The post-processing method is based on fully automatic registration of non-enhanced and contrast-enhanced CT data and subsequent selective bone removal. Vascular structures and brain tissue are retained with the original CTA noise level. Image quality and delineation of the pathologic process were assessed and artifacts introduced by the bone removal process recorded. The bone subtraction algorithm worked successfully in all examinations. The processing time was 6 min on average. Image quality was rated excellent in 20 (39%), good in 26 (51%) and acceptable in 5 (10%) patients. Ophthalmic arteries were visible in 12 (24%) patients bilaterally, in 13 (25%) patients unilaterally and in 26 (51%) patients at least at the origin. BSCTA improved visualization of the infraclinoid ICA and the vertebral arteries. The depiction of stenosis of the extracranial ICA and supraclinoid aneurysms was not significantly improved. In patients with suspicion of sinus thrombosis, BSCTA and conventional CTA yielded similar results. To conclude, BSCTA improves the visualization of vessels with close contact to bone and can improve the diagnostic accuracy and therapy planning of infraclinoid aneurysms.

PubMed Disclaimer

References

    1. Eur Radiol. 2004 Apr;14 (4):665-72 - PubMed
    1. Radiology. 1994 Sep;192(3):717-22 - PubMed
    1. Eur Radiol. 2005 Mar;15(3):408-15 - PubMed
    1. Med Phys. 2004 Oct;31(10 ):2924-33 - PubMed
    1. Neurosurgery. 1999 Dec;45(6):1315-20; discussion 1320-2 - PubMed

Publication types

LinkOut - more resources