Peak expiratory flow variability and bronchial responsiveness to methacholine. An epidemiologic study in 117 workers
- PMID: 1626818
- DOI: 10.1164/ajrccm/146.1.71
Peak expiratory flow variability and bronchial responsiveness to methacholine. An epidemiologic study in 117 workers
Abstract
We studied the relationships between peak expiratory flow (PEF) variability and bronchial responsiveness to methacholine in 117 workers attending the annual compulsory examination (mean age, 38.7 yr +/- 9.5; men, 86.3%). Subjects recorded their highest PEF out of three, every 3 waking hours (i.e., five times a day) for 7 days, each using a newly purchased Vitalograph peak flow meter, and underwent methacholine challenge tests with a maximal cumulative dose of 1,200 micrograms. Those with a FEV1 fall of 15% or more were considered as reactors. The variability of PEF was expressed as the amplitude percent mean, calculated from daily amplitude (highest-lowest reading/mean reading of the day x 100), averaged over 6 days, from the second to the seventh. This index had a continuous distribution, skewed towards the greatest amplitudes, and correlated negatively with FEV1 (r = -0.25, p = 0.01). Subjects with asthma (n = 8) had greater variations. In the 109 nonasthmatics, greater variability was observed in subjects with wheeze apart from colds, breathlessness, or hay fever; the average amplitude was greater in reactors than in nonreactors to methacholine (16.9% versus 9.3%, p less than 0.001). The subjects with excessive PEF variability were all methacholine reactors, but they were only a subgroup of the reactors. These results provide evidence that excessive PEF variability is an indicator of bronchial hyperresponsiveness to methacholine in a population sample.
Similar articles
-
Relationship between airway responsiveness and peak expiratory flow variability in subjects with allergic rhinitis.Ann Allergy Asthma Immunol. 1995 Sep;75(3):273-9. Ann Allergy Asthma Immunol. 1995. PMID: 7552931
-
Peak expiratory flow rate variability in population surveys. Does the number of assessments matter?Chest. 1995 Feb;107(2):418-23. doi: 10.1378/chest.107.2.418. Chest. 1995. PMID: 7842771
-
Relationships of methacholine and AMP responsiveness with peak expiratory flow variability in children with asthma.Clin Exp Allergy. 2007 Aug;37(8):1158-64. doi: 10.1111/j.1365-2222.2007.02766.x. Clin Exp Allergy. 2007. PMID: 17651145
-
PEF variability, bronchial responsiveness and their relation to allergy markers in a random population (20-70 yr).Am J Respir Crit Care Med. 1996 Jul;154(1):30-5. doi: 10.1164/ajrccm.154.1.8680695. Am J Respir Crit Care Med. 1996. PMID: 8680695
-
Variability of peak expiratory flow rate in allergic rhinitis and mild asthma: relationship to maximal airway narrowing.Ann Allergy Asthma Immunol. 1998 Feb;80(2):151-8. doi: 10.1016/S1081-1206(10)62948-1. Ann Allergy Asthma Immunol. 1998. PMID: 9494447
Cited by
-
Diurnal variability--time to change asthma guidelines?BMJ. 1999 Jul 3;319(7201):45-7. doi: 10.1136/bmj.319.7201.45. BMJ. 1999. PMID: 10390464 Free PMC article. No abstract available.
-
Chronic and acute respiratory effects among grain mill workers.Int Arch Occup Environ Health. 1995;67(5):311-5. doi: 10.1007/BF00385646. Int Arch Occup Environ Health. 1995. PMID: 8543379
-
Testing bronchial hyper-responsiveness: provocation or peak expiratory flow variability?Br J Gen Pract. 1997 Aug;47(421):487-92. Br J Gen Pract. 1997. PMID: 9302787 Free PMC article. Clinical Trial.
-
Diurnal Variation in Peak Expiratory Flow and Forced Expiratory Volume.J Clin Diagn Res. 2015 Oct;9(10):CC05-7. doi: 10.7860/JCDR/2015/15156.6661. Epub 2015 Oct 1. J Clin Diagn Res. 2015. PMID: 26557513 Free PMC article.
-
Relation between respiratory symptoms, pulmonary function and peak flow variability in adults.Thorax. 1995 Feb;50(2):121-6. doi: 10.1136/thx.50.2.121. Thorax. 1995. PMID: 7701448 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical