[Chitin biological tube bridging the peripheral nerve with a small gap]
- PMID: 16271251
[Chitin biological tube bridging the peripheral nerve with a small gap]
Abstract
Objective: To investigate the possibility of bridging small peripheral nerve gap using a de-acetyl chitosan conduit.
Methods: The sciatic nerves of right sides were cut at SD rats. They were divided into 5 Groups randomly; Group A: epineurium suture in situ (n = 24); Group B: biological conduit with a small gap for bridging the peripheral nerve (n = 24, with 5 mm gap); Group C: epineurium suture with distal stump rotated 180 degrees (n = 24); Group D: bridging the nerve by biological conduits with a small gap, but the distal stump rotated 180 degrees (n = 24, with 5 mm gap); Group E: biological conduit with a small gap for bridging the peripheral nerve with NGF (n = 24). Electrophysiological examination, histological examination and myelinated axon counting were applied after 2, 4, 6, 8 weeks after operation respectively.
Results: Regenerated nerve fibers were seen in the distal nerve segments of all 5 groups; The nerve conduction velocity of small gap group (group B, D) was faster than that of corresponding simple epineurium suture group (group A, C) at all 2, 4, 6, 8 week time point (P < 0.05). The myelinated axon counting of small gap group (group B, D) was faster than that of corresponding simple epineurium suture group (group A, C) at all 4, 6, 8 week time point (P < 0.01), and there was no statistically significant difference at 2 week time point.
Conclusion: The repair effects of chitin conduit bridging peripheral nerve with small gap (5 mm) are better than that of epineurium suture directly, and possess the potential to substitute the epineurium suture.
Similar articles
-
The experimental study of absorbable chitin conduit for bridging peripheral nerve defect with nerve fasciculu in rats.Artif Cells Blood Substit Immobil Biotechnol. 2008;36(4):360-71. doi: 10.1080/10731190802239040. Artif Cells Blood Substit Immobil Biotechnol. 2008. PMID: 18649171
-
The electrophysiology analysis of biological conduit sleeve bridging rhesus monkey median nerve injury with small gap.Artif Cells Blood Substit Immobil Biotechnol. 2008;36(5):457-63. doi: 10.1080/10731190802375802. Artif Cells Blood Substit Immobil Biotechnol. 2008. PMID: 18925468
-
[Magnifying effect of conduit bridging in number of nerve fibers of broken peripheral nerves: experiment with rats].Zhonghua Yi Xue Za Zhi. 2007 Apr 17;87(15):1043-7. Zhonghua Yi Xue Za Zhi. 2007. PMID: 17672969 Chinese.
-
Advances in small gap sleeve bridging peripheral nerve injury.Artif Cells Blood Substit Immobil Biotechnol. 2010;38(1):1-4. doi: 10.3109/10731190903495652. Artif Cells Blood Substit Immobil Biotechnol. 2010. PMID: 20064102 Review.
-
Biodegradable conduit small gap tubulization for peripheral nerve mutilation: a substitute for traditional epineurial neurorrhaphy.Int J Med Sci. 2013;10(2):171-5. doi: 10.7150/ijms.5312. Epub 2013 Jan 5. Int J Med Sci. 2013. PMID: 23329889 Free PMC article. Review.
Cited by
-
Repair of long segmental ulnar nerve defects in rats by several different kinds of nerve transposition.Neural Regen Res. 2019 Apr;14(4):692-698. doi: 10.4103/1673-5374.247473. Neural Regen Res. 2019. PMID: 30632510 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous