Primary stability of four different implants for opening wedge high tibial osteotomy
- PMID: 16284740
- DOI: 10.1007/s00167-005-0690-1
Primary stability of four different implants for opening wedge high tibial osteotomy
Abstract
Since a significant number of implant failures have been reported in association with the procedure of open wedge valgus high tibial osteotomy, the initial biomechanical stability of different fixation devices was investigated in this study. Fifteen third generation Sawbones composite tibiae were used as a model. Four different plates were tested: a short spacer plate (OWO) (n = 4), a short spacer plate with multi-directional locking bolts (MSO) (n = 5), a prototype version of a long spacer plate with multi-directional locking bolts (MSOnew) (n = 2), and a long medial tibia plate fixator with locking bolts (MPF) (n = 4). All opening wedge osteotomies were performed by the same surgeon (PL) in a standardized fashion. Axial compression of the tibiae was performed using a materials testing machine under standardized alignment of the loading axis. Single load to failure tests as well as load-controlled cyclical failure tests were performed. The required force and cycles to failure were recorded. Osteotomy gap motion was measured using linear displacement transducers. Residual stability after failure of the opposite lateral cortex was analysed. Failure occurred at the lateral cortex bone-bride in all tested implants. The rigid long plate fixator (MPF) resisted the greatest amount of force (2,881 N) in the single load to failure tests. In the cyclical load-to-failure tests, the constructs with MPF resisted more than twice the amount of loading cycles when compared to the short spacer plates. The osteotomy gap motion was smallest in the MPF, with a reduction of the displacements of up to 65, 66 and 88%, when compared to OWO, MSO and MSOnew, respectively. The highest residual stability after failure of the lateral cortex was observed in MPF as well. The results suggest that the implant design strongly influences the primary stability of medial opening wedge tibial osteotomy. A rigid long plate fixator with angle-stable locking bolts yields the best results.
Comment in
-
High tibial osteotomy and external fixator.Knee Surg Sports Traumatol Arthrosc. 2006 Oct;14(10):1033-4; author reply 1035-6. doi: 10.1007/s00167-006-0194-7. Epub 2006 Sep 2. Knee Surg Sports Traumatol Arthrosc. 2006. PMID: 16951972 No abstract available.
Similar articles
-
Effect of a biplanar osteotomy on primary stability following high tibial osteotomy: a biomechanical cadaver study.Knee Surg Sports Traumatol Arthrosc. 2010 Feb;18(2):204-11. doi: 10.1007/s00167-009-0929-3. Epub 2009 Oct 7. Knee Surg Sports Traumatol Arthrosc. 2010. PMID: 19809806 Clinical Trial.
-
Biomechanical investigation of different internal fixations in medial opening-wedge high tibial osteotomy.Clin Biomech (Bristol). 2006 Mar;21(3):272-8. doi: 10.1016/j.clinbiomech.2005.10.010. Epub 2005 Dec 7. Clin Biomech (Bristol). 2006. PMID: 16337721
-
Intramedullary nailing in opening wedge high tibial osteotomy-in vitro test for validation of a method of fixation.Int Orthop. 2018 Aug;42(8):1835-1843. doi: 10.1007/s00264-018-3790-5. Epub 2018 Feb 1. Int Orthop. 2018. PMID: 29392383
-
Biomechanical comparison of two alternative tibial plateau leveling osteotomy plates with the original standard in an axially loaded gap model: an in vitro study.Vet Surg. 2009 Jan;38(1):40-8. doi: 10.1111/j.1532-950X.2008.00464.x. Vet Surg. 2009. PMID: 19152616
-
[Biomechanical study of four palmar locking plates and one non-locking palmar plate for distal radius fractures: stiffness and load to failure tests in a cadaver model].Biomed Tech (Berl). 2009 Jun;54(3):150-8. doi: 10.1515/BMT.2009.018. Biomed Tech (Berl). 2009. PMID: 19469665 Review. German.
Cited by
-
Bovine xenograft locking Puddu plate versus tricalcium phosphate spacer non-locking Puddu plate in opening-wedge high tibial osteotomy: a prospective double-cohort study.Int Orthop. 2013 May;37(5):819-26. doi: 10.1007/s00264-013-1817-5. Epub 2013 Feb 15. Int Orthop. 2013. PMID: 23412369 Free PMC article.
-
Open-wedge high tibial osteotomy: incidence of lateral cortex fractures and influence of fixation device on osteotomy healing.Knee Surg Sports Traumatol Arthrosc. 2017 Mar;25(3):832-837. doi: 10.1007/s00167-015-3730-5. Epub 2015 Aug 8. Knee Surg Sports Traumatol Arthrosc. 2017. PMID: 26254088
-
Results of high tibial osteotomy: review of the literature.Int Orthop. 2010 Feb;34(2):155-60. doi: 10.1007/s00264-009-0889-8. Epub 2009 Oct 17. Int Orthop. 2010. PMID: 19838706 Free PMC article. Review.
-
Safety of a novel high tibial osteotomy locked plate fixation for immediate full weight-bearing: a case-control study.Int Orthop. 2013 Dec;37(12):2377-84. doi: 10.1007/s00264-013-2066-3. Epub 2013 Aug 24. Int Orthop. 2013. PMID: 23974839 Free PMC article.
-
Clinical outcome and return to work following single-stage combined autologous chondrocyte implantation and high tibial osteotomy.Int Orthop. 2015 Apr;39(4):689-96. doi: 10.1007/s00264-014-2547-z. Epub 2014 Oct 10. Int Orthop. 2015. PMID: 25300396
References
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous