. 2006 Mar;14(3):291-300.
doi: 10.1007/s00167-005-0690-1. Epub 2005 Nov 12.

Primary stability of four different implants for opening wedge high tibial osteotomy

Affiliations

Primary stability of four different implants for opening wedge high tibial osteotomy

J D Agneskirchner et al. Knee Surg Sports Traumatol Arthrosc. 2006 Mar.

Abstract

Since a significant number of implant failures have been reported in association with the procedure of open wedge valgus high tibial osteotomy, the initial biomechanical stability of different fixation devices was investigated in this study. Fifteen third generation Sawbones composite tibiae were used as a model. Four different plates were tested: a short spacer plate (OWO) (n = 4), a short spacer plate with multi-directional locking bolts (MSO) (n = 5), a prototype version of a long spacer plate with multi-directional locking bolts (MSOnew) (n = 2), and a long medial tibia plate fixator with locking bolts (MPF) (n = 4). All opening wedge osteotomies were performed by the same surgeon (PL) in a standardized fashion. Axial compression of the tibiae was performed using a materials testing machine under standardized alignment of the loading axis. Single load to failure tests as well as load-controlled cyclical failure tests were performed. The required force and cycles to failure were recorded. Osteotomy gap motion was measured using linear displacement transducers. Residual stability after failure of the opposite lateral cortex was analysed. Failure occurred at the lateral cortex bone-bride in all tested implants. The rigid long plate fixator (MPF) resisted the greatest amount of force (2,881 N) in the single load to failure tests. In the cyclical load-to-failure tests, the constructs with MPF resisted more than twice the amount of loading cycles when compared to the short spacer plates. The osteotomy gap motion was smallest in the MPF, with a reduction of the displacements of up to 65, 66 and 88%, when compared to OWO, MSO and MSOnew, respectively. The highest residual stability after failure of the lateral cortex was observed in MPF as well. The results suggest that the implant design strongly influences the primary stability of medial opening wedge tibial osteotomy. A rigid long plate fixator with angle-stable locking bolts yields the best results.

PubMed Disclaimer

Comment in

  • High tibial osteotomy and external fixator.
    Cebesoy O, Karakurum G, Arpacioglu O. Cebesoy O, et al. Knee Surg Sports Traumatol Arthrosc. 2006 Oct;14(10):1033-4; author reply 1035-6. doi: 10.1007/s00167-006-0194-7. Epub 2006 Sep 2. Knee Surg Sports Traumatol Arthrosc. 2006. PMID: 16951972 No abstract available.

Similar articles

Cited by

References

    1. Arch Orthop Trauma Surg. 1999;119(7-8):450-5 - PubMed
    1. Knee Surg Sports Traumatol Arthrosc. 2003 May;11(3):132-8 - PubMed
    1. Acta Orthop Scand. 1990 Apr;61(2):128-30 - PubMed
    1. Rev Chir Orthop Reparatrice Appar Mot. 1993;79(5):375-84 - PubMed
    1. Orthopedics. 1999 Aug;22(8):729-36 - PubMed

LinkOut - more resources