Flow cytometric immunophenotyping: principles and pitfalls
- PMID: 1628666
- DOI: 10.1007/BF01959351
Flow cytometric immunophenotyping: principles and pitfalls
Abstract
Within the last decade flow cytometry (FCM) has become an integral part of basic immunological research. Elaboration of this technology has been intensively stimulated by a rapidly growing sophistication in monoclonal antibody technology and vice versa. At present numerous applications are established that allow an increasingly detailed insight into the immune system, however, automation still must be considered the "cinderella of the arts". Thus, transition of this powerful approach from a basic to a routine clinical procedure is much more difficult than expected. Sufficient usage of flow cytometers still requires some knowledge of physics and its technical applications. Moreover, several problems arise from the complexity of the biological systems investigated. Here we give a brief introduction to immunofluorescence and FCM followed by a discussion of six exemplary pitfalls that we hope will emphasise the general importance of methodological considerations.
Similar articles
-
Clinical flow cytometry: milestones along the pathway of progress.MLO Med Lab Obs. 2002 Sep;34(9):10-1, 14-6; quiz 20-1. MLO Med Lab Obs. 2002. PMID: 12239984 Review. No abstract available.
-
A practical approach to multicolor flow cytometry for immunophenotyping.J Immunol Methods. 2000 Sep 21;243(1-2):77-97. doi: 10.1016/s0022-1759(00)00229-5. J Immunol Methods. 2000. PMID: 10986408 Review.
-
Fluorescence-intensity multiplexing: simultaneous seven-marker, two-color immunophenotyping using flow cytometry.Cytometry A. 2004 Oct;61(2):142-52. doi: 10.1002/cyto.a.20037. Cytometry A. 2004. PMID: 15382027
-
Light scatter as an adjunct to cellular immunofluorescence in flow cytometric systems.J Clin Immunol. 1982 Jul;2(3 Suppl):32S-41S. J Clin Immunol. 1982. PMID: 6752177
-
Immunophenotyping.Curr Protoc Cytom. 2001 May;Chapter 6:Unit 6.2. doi: 10.1002/0471142956.cy0602s00. Curr Protoc Cytom. 2001. PMID: 18770715
Cited by
-
Probing cell membrane integrity using a histone-targeting protein nanocage displaying precisely positioned fluorophores.Nano Res. 2023;16(1):894-904. doi: 10.1007/s12274-022-4785-5. Epub 2022 Sep 2. Nano Res. 2023. PMID: 36090614 Free PMC article.
-
Optimization of a Method to Isolate and Culture Adult Porcine, Rats and Mice Müller Glia in Order to Study Retinal Diseases.Front Cell Neurosci. 2020 Jan 29;14:7. doi: 10.3389/fncel.2020.00007. eCollection 2020. Front Cell Neurosci. 2020. PMID: 32082123 Free PMC article.
-
Lymphocyte subpopulations in newborns.Eur J Pediatr. 1995 May;154(5):419-21. doi: 10.1007/BF02072122. Eur J Pediatr. 1995. PMID: 7641782 No abstract available.
-
Interleukin-10, T-lymphocytes, and cardiac output in children after ventricular septal defect repair: a pilot study.Intensive Care Med. 2006 May;32(5):780-4. doi: 10.1007/s00134-006-0141-6. Epub 2006 Mar 21. Intensive Care Med. 2006. PMID: 16550368
-
Flow cytometry. Principles and applications in exercise immunology.Sports Med. 1995 Nov;20(5):302-20. doi: 10.2165/00007256-199520050-00002. Sports Med. 1995. PMID: 8571004 Review. No abstract available.