Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2005 Dec;77(3):318-23.
doi: 10.1016/j.radonc.2005.09.018. Epub 2005 Nov 11.

Measurement of prostate rotation during insertion of needles for brachytherapy

Affiliations
Clinical Trial

Measurement of prostate rotation during insertion of needles for brachytherapy

Vera Lagerburg et al. Radiother Oncol. 2005 Dec.

Abstract

Background and purpose: The purpose of this study is to investigate whether prostate rotation due to needle insertion for prostate brachytherapy is predictable and if so, to quantify this rotation, and to see whether locking needles reduce the magnitude of prostate rotation.

Patients and methods: The measurements are done at the beginning of the procedure for brachytherapy with a Foley catheter in situ. After a needle is inserted into the prostate, a 3D ultrasound scan is made. Then the seeds are delivered using RAPID Strands (Oncura), and the needle is withdrawn. A second 3D scan is made. The needle and seed positions are determined in these scans. To determine the rotation of the prostate, the angle between the needle and the seed trajectory is calculated.

Results: The prostate rotations have been measured in 16 patients, eight without the use of locking needles and eight with locking needles. In total 62 needles were inserted. The maximum rotation was 13.8 degrees and occurred in the coronal plane when no locking needles were used with a significant correlation (P<0.01, R=0.637) between the place of insertion and rotation. It was shown that the method (with or without locking needles) had a significant (P<0.001) influence on the rotation in the coronal plane. Rotations in the sagittal plane ranged from -8.5 degrees to +10.2 degrees without correlation with the insertion point of the needle or the use of locking needles.

Conclusions: This study showed that prostate rotation during needle insertion for prostate brachytherapy is relatively large and unpredictable. Locking needles reduce prostate rotation in the coronal plane, but not in the sagittal plane. Minimising this rotation is necessary for accurate seed delivery, especially when a robotic implantation technique is used.

PubMed Disclaimer

Publication types

LinkOut - more resources