Accuracy of ultrasound in the detection of liver fibrosis in chronic viral hepatitis
- PMID: 16292241
Accuracy of ultrasound in the detection of liver fibrosis in chronic viral hepatitis
Abstract
Purpose: To assess the accuracy of ultrasonography (US) in the identification and grading of hepatic fibrosis in patients afflicted with chronic viral liver disease, compared to histological examination as a gold standard.
Materials and methods: We prospectively studied 105 patients (32 F, 73 M) affected by chronic viral liver disease in 36 months. Patients were studied with B-mode US and then underwent US-guided liver biopsy. All the patients were studied with conventional US with a Sequoia 512, 6.0 (Acuson, Mountain View CA, USA). We evaluated the following US parameters: liver margins, parenchymal echotexture, portal vein caliber and spleen diameter. The four B-mode US parameters were used for the US grading (from 0 to 4). Scheuer's grading (from 0 to 4) was used for the histological score. Grades 3 and 4 were considered as positive for fibrosis. Sensitivity, specificity, positive and negative predictive values and accuracy were calculated in the case of absence, positivity of one or all the US parameters. The correlation between US and histological scores was evaluated with Spearman's test.
Results: At histology seventy-seven patients (73%) had absent grade 0 (1 patient; 1%), low-moderate grade 1 (35 patients; 33%) or grade 2 (41 patients; 39%) liver fibrosis. Twenty-eight patients (27%) had severe grade 3 (16 patients; 15%) or grade 4 (12 patients; 11%) fibrosis. In the case of absence of US parameters sensitivity was 32%, specificity 32%, positive predictive value 15%, negative predictive value 57% and accuracy 32%. In the case of positivity of at least one of the US parameters the values were 68%, 68%, 43%, 84% and 69%. In the case of presence of all the US signs the results were 25%, 100%, 100%, 79% and 80%. None of the 77 patients with a healthy liver or with low-grade fibrosis was positive for all the US parameters. All the patients positive for all of the ultrasonographic parameters had high-grade fibrosis or cirrhosis at liver biopsy. Correlation between B-mode and histological scores was not statistically significant (Rs=0.45; p=0.0001).
Conclusions: US identification of liver fibrosis in chronic liver disease is possible with 25% sensitivity, 100% specificity, 100% positive predictive value and 79% negative predictive value, with an 80% diagnostic accuracy.
Similar articles
-
Correlation between ultrasonographic and pathologic diagnosis of liver fibrosis due to chronic virus hepatitis.World J Gastroenterol. 2006 Feb 28;12(8):1292-5. doi: 10.3748/wjg.v12.i8.1292. World J Gastroenterol. 2006. PMID: 16534888 Free PMC article.
-
Correlation between ultrasonographic and pathologic diagnoses of hepatitis B and C virus-related cirrhosis.J Gastroenterol. 2003;38(2):153-7. doi: 10.1007/s005350300025. J Gastroenterol. 2003. PMID: 12640529
-
Ultrasonographic and biochemical parameters in the non-invasive evaluation of liver fibrosis in hepatitis C virus chronic hepatitis.Aliment Pharmacol Ther. 2005 Nov 1;22(9):769-74. doi: 10.1111/j.1365-2036.2005.02633.x. Aliment Pharmacol Ther. 2005. PMID: 16225484
-
Diagnosis of fibrosis and cirrhosis. Liver biopsy is not always necessary.Prescrire Int. 2010 Feb;19(105):38-42. Prescrire Int. 2010. PMID: 20455345 Review.
-
Improved diagnostic accuracy of blood tests for severe fibrosis and cirrhosis in chronic hepatitis C.Eur J Gastroenterol Hepatol. 2009 Jan;21(1):28-38. doi: 10.1097/MEG.0b013e32830cebd7. Eur J Gastroenterol Hepatol. 2009. PMID: 19060630 Review.
Cited by
-
Diagnosis of liver cirrhosis by transit-time analysis at contrast-enhanced ultrasonography.Radiol Med. 2008 Sep;113(6):860-74. doi: 10.1007/s11547-008-0292-3. Epub 2008 Jun 27. Radiol Med. 2008. PMID: 18587531 English, Italian.
-
Ultrasound Accuracy of Liver Length Measurement with Cadaveric Specimens.J Diagn Med Sonogr. 2016 Jan-Feb;32(1):12-19. doi: 10.1177/8756479315621287. J Diagn Med Sonogr. 2016. PMID: 26966729 Free PMC article.
-
Non-invasive assessment of fibrosis using color Doppler ultrasound in patients with hepatitis C virus in the Amazon rainforest, Brazil.Am J Trop Med Hyg. 2012 Feb;86(2):273-9. doi: 10.4269/ajtmh.2012.11-0561. Am J Trop Med Hyg. 2012. PMID: 22302863 Free PMC article.
-
Liver Fibrosis Conventional and Molecular Imaging Diagnosis Update.J Liver. 2019;8(1):236. Epub 2019 Jan 22. J Liver. 2019. PMID: 31341723 Free PMC article.
-
Discordance between conventional ultrasonography and ElastPQ for assessing hepatic fibrosis in chronic hepatitis B: frequency and independent factors.J Med Ultrason (2001). 2016 Apr;43(2):201-10. doi: 10.1007/s10396-015-0684-7. Epub 2015 Nov 5. J Med Ultrason (2001). 2016. PMID: 27033866
MeSH terms
LinkOut - more resources
Medical