Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2005 Dec;12(12):1206-15.
doi: 10.1197/j.aem.2005.07.018. Epub 2005 Nov 17.

Factors associated with failure of noninvasive positive pressure ventilation in the emergency department

Affiliations
Free article
Comparative Study

Factors associated with failure of noninvasive positive pressure ventilation in the emergency department

Paolo G Merlani et al. Acad Emerg Med. 2005 Dec.
Free article

Abstract

Objectives: To determine the factors associated with failure of noninvasive positive pressure ventilation (NPPV) in patients presenting with acute respiratory failure to the emergency department (ED).

Methods: The authors retrospectively analyzed patients admitted to the ED for acute respiratory failure (defined as a PaCO2 level >45 mm Hg, and pH < or = 7.35 or a PaO2/FiO2 ratio < 250 mm Hg) and who were treated with NPPV. NPPV was delivered routinely according to an institutional protocol. Failure of NPPV was defined as the requirement of endotracheal intubation at any time.

Results: A total of 104 patients were included. NPPV failed in 31% (32/104), and the mortality was significantly higher in this group (12/32 [44%]) compared with patients who were not intubated (2/72 [3%]) (p < 0.0001). Factors associated with failure of NPPV were Glasgow Coma Scale score < 13 at ED admission (odds ratio [OR], 3.67; 95% confidence interval [CI] = 1.33 to 10.07), pH < or = 7.35 (OR, 3.23; 95% CI = 1.25 to 8.31), and respiratory rate (RR) > or =20 min(-1) (OR, 3.86; 95% CI = 1.33 to 11.17) after one hour of NPPV. The negative predictive value for NPPV failure was 86% (95% CI = 70% to 95%) for RR > or =20 min(-1). In the multivariate analysis, pH < or = 7.35 and RR > or =20 min(-1) after one hour of NPPV were independently associated with NPPV failure (adjusted ORs, 3.51; 95% CI = 1.29 to 9.62 and 3.55; 95% CI = 1.13 to 11.20, respectively).

Conclusions: Patients with pH < or = 7.35 and an RR > or =20 min(-1) after one hour of NPPV had an increased risk of subsequent endotracheal intubation.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources