Deep tissue two-photon microscopy
- PMID: 16299478
- DOI: 10.1038/nmeth818
Deep tissue two-photon microscopy
Erratum in
- Nat Methods. 2006 Mar;3(3):235
Abstract
With few exceptions biological tissues strongly scatter light, making high-resolution deep imaging impossible for traditional-including confocal-fluorescence microscopy. Nonlinear optical microscopy, in particular two photon-excited fluorescence microscopy, has overcome this limitation, providing large depth penetration mainly because even multiply scattered signal photons can be assigned to their origin as the result of localized nonlinear signal generation. Two-photon microscopy thus allows cellular imaging several hundred microns deep in various organs of living animals. Here we review fundamental concepts of nonlinear microscopy and discuss conditions relevant for achieving large imaging depths in intact tissue.
Similar articles
-
Two-photon microscopy of cells and tissue.Circ Res. 2004 Dec 10;95(12):1154-66. doi: 10.1161/01.RES.0000150593.30324.42. Circ Res. 2004. PMID: 15591237 Review.
-
Multiphoton intravital microscopy in small animals: motion artefact challenges and technical solutions.J Microsc. 2020 Apr;278(1):3-17. doi: 10.1111/jmi.12880. Epub 2020 Mar 5. J Microsc. 2020. PMID: 32072642 Free PMC article. Review.
-
Non-invasive imaging of skin physiology and percutaneous penetration using fluorescence spectral and lifetime imaging with multiphoton and confocal microscopy.Eur J Pharm Biopharm. 2011 Apr;77(3):469-88. doi: 10.1016/j.ejpb.2010.12.023. Epub 2011 Jan 21. Eur J Pharm Biopharm. 2011. PMID: 21256962 Review.
-
Tissue Clearing and Deep Imaging of the Kidney Using Confocal and Two-Photon Microscopy.Methods Mol Biol. 2020;2067:103-126. doi: 10.1007/978-1-4939-9841-8_8. Methods Mol Biol. 2020. PMID: 31701448
-
Adding new dimensions to laser-scanning fluorescence microscopy.J Microsc. 2009 Feb;233(2):320-5. doi: 10.1111/j.1365-2818.2009.03122.x. J Microsc. 2009. PMID: 19220698
Cited by
-
Amplifying transmission and compact suspension for a low-profile, large-displacement piezoelectric actuator.J Micromech Microeng. 2011 Jun 1;21(6):067004. doi: 10.1088/0960-1317/21/6/067004. Epub 2011 May 11. J Micromech Microeng. 2011. PMID: 23180908 Free PMC article.
-
CLARITY for mapping the nervous system.Nat Methods. 2013 Jun;10(6):508-13. doi: 10.1038/nmeth.2481. Nat Methods. 2013. PMID: 23722210
-
Non-degenerate two-photon imaging of deep rodent cortex using indocyanine green in the water absorption window.Biomed Opt Express. 2024 Aug 6;15(9):5053-5066. doi: 10.1364/BOE.520977. eCollection 2024 Sep 1. Biomed Opt Express. 2024. PMID: 39296386 Free PMC article.
-
Extended field-of-view ultrathin microendoscopes for high-resolution two-photon imaging with minimal invasiveness.Elife. 2020 Oct 13;9:e58882. doi: 10.7554/eLife.58882. Elife. 2020. PMID: 33048047 Free PMC article.
-
Imaging and tracking of bone marrow-derived immune and stem cells.Methods Mol Biol. 2013;1052:57-76. doi: 10.1007/7651_2013_28. Methods Mol Biol. 2013. PMID: 23737096 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources