The harmonization of quantitative test results of different D-dimer methods
- PMID: 16302153
- DOI: 10.1055/s-2005-922477
The harmonization of quantitative test results of different D-dimer methods
Abstract
Nowadays D-dimer testing is frequently applied in the diagnosis of venous thromboembolism. However, the test results of different quantitative D-dimer tests can differ significantly. The background of this variability, which is mainly caused by the variety of fibrin degradation products in plasma, the specificity of D-dimer assays, and the calibrators used in the test, is summarized here. Because D-dimer is not a single entity in plasma but a mixture of heterogeneous fibrin degradation products, method standardization is in principle impossible. Efforts undertaken in the past to standardize D-dimer methods are summarized. All these projects failed and it was concluded that only harmonization of D-dimer test results seems to be feasible. The results of a large field study on which a new approach to the harmonization of quantitative D-dimer methods will be based is summarized in this article. This approach seems to be an adequate solution for overcoming the practical problem of variation of test outcome in different D-dimer assays.
Similar articles
-
Validation, calibration, and specificity of quantitative D-dimer assays.Semin Vasc Med. 2005 Nov;5(4):315-20. doi: 10.1055/s-2005-922476. Semin Vasc Med. 2005. PMID: 16302152 Review.
-
Comparability of D-dimer assays in clinical samples.Semin Vasc Med. 2005 Nov;5(4):328-39. doi: 10.1055/s-2005-922478. Semin Vasc Med. 2005. PMID: 16302154 Review.
-
[D-dimer analysis in diagnosis of venous thromboembolism is reliable].Lakartidningen. 2004 Oct 7;101(41):3152, 3154-5. Lakartidningen. 2004. PMID: 15517710 Swedish.
-
The Fibrin Assay Comparison Trial (FACT): evaluation of 23 quantitative D-dimer assays as basis for the development of D-dimer calibrators. FACT study group.Thromb Haemost. 2001 Apr;85(4):671-8. Thromb Haemost. 2001. PMID: 11341504
-
Diagnosis accuracy of a new challenger for thrombosis exclusion, the Stratus CS DDMR.Clin Chim Acta. 2005 Apr;354(1-2):181-9. doi: 10.1016/j.cccn.2004.11.027. Clin Chim Acta. 2005. PMID: 15748615
Cited by
-
Monoclonal antibodies with equal specificity to D-dimer and high-molecular-weight fibrin degradation products.Blood Coagul Fibrinolysis. 2016 Jul;27(5):542-50. doi: 10.1097/MBC.0000000000000453. Blood Coagul Fibrinolysis. 2016. PMID: 26656897 Free PMC article.
-
Harmonized D-dimer levels upon admission for prognosis of COVID-19 severity: Results from a Spanish multicenter registry (BIOCOVID-Spain study).J Thromb Thrombolysis. 2022 Jan;53(1):103-112. doi: 10.1007/s11239-021-02527-y. Epub 2021 Jul 16. J Thromb Thrombolysis. 2022. PMID: 34272635 Free PMC article.
-
Excluding venous thromboembolism using point of care D-dimer tests in outpatients: a diagnostic meta-analysis.BMJ. 2009 Aug 14;339:b2990. doi: 10.1136/bmj.b2990. BMJ. 2009. PMID: 19684102 Free PMC article.
-
Advances in D-dimer testing: progress in harmonization of clinical assays and innovative detection methods.Anal Bioanal Chem. 2024 Jul;416(16):3737-3750. doi: 10.1007/s00216-024-05207-x. Epub 2024 Mar 20. Anal Bioanal Chem. 2024. PMID: 38503987 Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous