Stentless aortic valves are hemodynamically superior to stented valves during mid-term follow-up: a large retrospective study
- PMID: 16305867
- DOI: 10.1016/j.athoracsur.2005.05.055
Stentless aortic valves are hemodynamically superior to stented valves during mid-term follow-up: a large retrospective study
Abstract
Background: Several studies have compared left venticular mass (LVM) regression and hemodynamic data for stentless versus stented aortic bioprostheses with conflicting results. The major limitations of these studies are their small sample size and short-term follow-up. We therefore compared midterm LVM regression, hemodynamic data, and survival in a large population of tissue aortic valve replacement (AVR) patients.
Methods: All patients undergoing tissue AVR at our institution between 1998 and 2001 were included (n = 737). Patients were divided into two groups according to type of bioprosthetic implanted: stentless patients (total n = 310) (Toronto SPV [St Jude Medical, St Paul, MN], n = 146 and Freestyle [Medtronic, Minneapolis, MN], n = 164) and stented patients (total n = 427) (Perimount [Edwards Life Sciences Inc, Irvine, CA], n = 291 and Mosaic [Medtronic], n = 136).
Results: The two groups of patients had similar preoperative transvalvular gradients and LVM index (130 +/- 47 vs 130 +/- 42 g/m2 for stentless versus stented valves, respectively). Predischarge echos revealed that stentless patients had significantly lower mean transvalvular gradients (11 +/- 5 vs 15 +/- 6 mm Hg, p < 0.001) and larger effective orifice areas (1.32 +/- 0.52 vs 1.22 +/- 0.48 cm2, p = 0.01). Follow-up echocardiograms were obtained in 99% of surviving patients 28 +/- 22 (range, 0-79) months postoperatively. Stentless patients had significantly lower LVM index during follow-up (100 +/- 32 vs 107 +/- 32 g/m2, p = 0.005) and stentless valves were an independent predictor of LVM regression. Furthermore, a higher proportion of stented patients had residual LV hypertrophy during follow-up (28% vs 18%, p = 0.001). Stentless valves were associated with improved midterm survival by univariate analysis, but not by multivariable analysis.
Conclusions: Midterm follow-up in a large number of patients reveals that stentless bioprostheses are hemodynamically superior to stented valves.
Similar articles
-
Are stentless valves hemodynamically superior to stented valves? Long-term follow-up of a randomized trial comparing Carpentier-Edwards pericardial valve with the Toronto Stentless Porcine Valve.J Thorac Cardiovasc Surg. 2010 Apr;139(4):848-59. doi: 10.1016/j.jtcvs.2009.04.067. Epub 2010 Jan 18. J Thorac Cardiovasc Surg. 2010. PMID: 20080264 Clinical Trial.
-
The Toronto root stentless valve in the subcoronary position is hemodynamically superior to the mosaic stented completely supra-annular bioprosthesis.J Heart Valve Dis. 2005 Nov;14(6):814-21; discussion 821. J Heart Valve Dis. 2005. PMID: 16359064
-
Meta-analysis of valve hemodynamics and left ventricular mass regression for stentless versus stented aortic valves.Ann Thorac Surg. 2007 Jul;84(1):73-8. doi: 10.1016/j.athoracsur.2007.02.057. Ann Thorac Surg. 2007. PMID: 17588387
-
Stentless valves for aortic valve replacement: where do we stand?Curr Opin Cardiol. 2007 Mar;22(2):96-103. doi: 10.1097/HCO.0b013e328014670a. Curr Opin Cardiol. 2007. PMID: 17284987 Review.
-
Which patients benefit from stentless aortic valve replacement?Ann Thorac Surg. 2009 Dec;88(6):2061-8. doi: 10.1016/j.athoracsur.2009.06.060. Ann Thorac Surg. 2009. PMID: 19932303 Review.
Cited by
-
In-vivo assessment of the morphology and hemodynamic functions of the BioValsalva™ composite valve-conduit graft using cardiac magnetic resonance imaging and computational modelling technology.J Cardiothorac Surg. 2014 Dec 9;9:193. doi: 10.1186/s13019-014-0193-6. J Cardiothorac Surg. 2014. PMID: 25488105 Free PMC article.
-
Long-Term Results (up to 20 Years) of 19 mm or Smaller Prostheses in the Aortic Position. Does Size Matter? A Propensity-Matched Survival Analysis.J Clin Med. 2021 May 11;10(10):2055. doi: 10.3390/jcm10102055. J Clin Med. 2021. PMID: 34064845 Free PMC article.
-
Hemodynamics of Pericardial Aortic Valves: Contemporary Stented versus Stentless Valves in a Matched Comparison.Ann Thorac Cardiovasc Surg. 2017 Dec 20;23(6):298-303. doi: 10.5761/atcs.oa.17-00061. Epub 2017 Sep 8. Ann Thorac Cardiovasc Surg. 2017. PMID: 28890465 Free PMC article.
-
Early failure secondary to noncoronary leaflet prolapse in a stentless aortic bioprosthesis.Tex Heart Inst J. 2012;39(5):676-9. Tex Heart Inst J. 2012. PMID: 23109766 Free PMC article.
-
Stentless aortic valve replacement in the young patient: long-term results.J Cardiothorac Surg. 2013 Apr 8;8:68. doi: 10.1186/1749-8090-8-68. J Cardiothorac Surg. 2013. PMID: 23566631 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources