Core needle biopsy versus fine needle aspiration biopsy: are there similar sampling and diagnostic issues?
- PMID: 16308086
- DOI: 10.1016/j.cll.2005.08.006
Core needle biopsy versus fine needle aspiration biopsy: are there similar sampling and diagnostic issues?
Abstract
Evidence suggests that in experienced hands fine needle aspiration biopsy (FNAB) is highly safe and effective for the evaluation of patients who have palpable breast lesions. In most cases, FNAB leads to an appropriate clinical or surgical management. FNAB can also be effectively used in evaluation of cystic lesions under ultrasound guidance. Other nonpalpable lesions can benefit from image-directed core needle biopsy (CNB). Overall, cost should influence the decision to use FNAB or CNB. FNAB may be the only affordable procedure in developing countries. Breast cancer affects significant numbers of women worldwide. Attempts should be made to take all the measures necessary to consider optimal approaches to breast health care for everyone regardless of age, race, ethnicity, or social status.
Similar articles
-
Large-core needle biopsy versus fine-needle aspiration biopsy in solid breast lesions: comparison of costs and diagnostic value.Acta Radiol. 2008 Oct;49(8):863-9. doi: 10.1080/02841850802235751. Acta Radiol. 2008. PMID: 18618302
-
Comparative cost-effectiveness of fine needle aspiration biopsy versus image-guided biopsy, and open surgical biopsy in the evaluation of breast cancer in the era of Affordable Care Act: a changing landscape.Diagn Cytopathol. 2015 Aug;43(8):605-12. doi: 10.1002/dc.23270. Epub 2015 Feb 26. Diagn Cytopathol. 2015. PMID: 25722099
-
The potential value of mammographically guided fine-needle aspiration biopsy of nonpalpable breast lesions.Am Surg. 1989 Apr;55(4):226-31. Am Surg. 1989. PMID: 2705686
-
[Fine-needle cytology and core biopsy of nonpalpable breast lesions. When appropriate?].Arch Anat Cytol Pathol. 1998;46(4):219-21. Arch Anat Cytol Pathol. 1998. PMID: 9754380 Review. French.
-
Image-guided breast biopsy: state-of-the-art.Clin Radiol. 2010 Apr;65(4):259-70. doi: 10.1016/j.crad.2010.01.008. Clin Radiol. 2010. PMID: 20338392 Review.
Cited by
-
Main controversies in breast cancer.World J Clin Oncol. 2014 Aug 10;5(3):359-73. doi: 10.5306/wjco.v5.i3.359. World J Clin Oncol. 2014. PMID: 25114851 Free PMC article. Review.
-
Experience in large-core needle biopsy in the diagnosis of 1431 breast lesions.Med Oncol. 2011 Jun;28(2):429-33. doi: 10.1007/s12032-010-9494-3. Epub 2010 Mar 26. Med Oncol. 2011. PMID: 20339957
-
Syringe and needle size, syringe type, vacuum generation, and needle control in aspiration procedures.Cardiovasc Intervent Radiol. 2011 Jun;34(3):590-600. doi: 10.1007/s00270-010-0011-z. Epub 2010 Nov 6. Cardiovasc Intervent Radiol. 2011. PMID: 21057795 Free PMC article. Clinical Trial.
-
Image-directed fine-needle aspiration biopsy of the thyroid with safety-engineered devices.Cardiovasc Intervent Radiol. 2011 Oct;34(5):1006-13. doi: 10.1007/s00270-010-0013-x. Epub 2010 Nov 6. Cardiovasc Intervent Radiol. 2011. PMID: 21057794 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical