Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Case Reports
. 2005 Nov 15;227(10):1613-7, 1591.
doi: 10.2460/javma.2005.227.1613.

Sarcoma of the proximal portion of the tibia in a dog 5.5 years after tibial plateau leveling osteotomy

Affiliations
Free article
Case Reports

Sarcoma of the proximal portion of the tibia in a dog 5.5 years after tibial plateau leveling osteotomy

Randy J Boudrieau et al. J Am Vet Med Assoc. .
Free article

Abstract

Osseous neoplasia was identified in the proximal portion of the tibia and distal portion of the femur in an 11.75-year-old spayed female German Shepherd Dog. A tibial plateau leveling osteotomy, followed by application of a metal plate, had been performed on the affected limb 5.5 years earlier. Areas of osteolysis and periosteal proliferation were seen radiographically, with an intense area of osteolysis directly beneath the metal plate. Histologically, the tumor was identified as a poorly differentiated sarcoma. Extracellular and intracellular debris was seen histologically, and energy-dispersive x-ray analysis confirmed that this debris was metallic. On visual examination, areas of the underside of the metal plate that had been in contact with bone had a dull, roughened appearance, and scanning electron microscopy of these areas revealed multiple corrosion pits. The plate was strongly magnetic, suggesting that it contained ferrite, and metallographic examination of the plate revealed substantial differences in the chemical makeup of various parts of the plate. Microstructure analysis revealed that the plate consisted of an austenite matrix with a large fraction of ferrite. The plate was determined to be a cast 316L stainless steel implant, but it did not meet American Society for Testing Materials standards for implant-grade materials. The possibility that implant corrosion might have played a role in tumor development is of concern; however, a definitive association was not established.

PubMed Disclaimer

Comment in

Publication types

MeSH terms

LinkOut - more resources