Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2006 Jan 27;1103(2):211-8.
doi: 10.1016/j.chroma.2005.11.010. Epub 2005 Dec 1.

Miniaturized membrane-assisted solvent extraction combined with gas chromatography/electron-capture detection applied to the analysis of volatile organic compounds

Affiliations

Miniaturized membrane-assisted solvent extraction combined with gas chromatography/electron-capture detection applied to the analysis of volatile organic compounds

Manuela Schellin et al. J Chromatogr A. .

Abstract

A new module of membrane-assisted solvent extraction (MASE) with miniaturized membrane bags was applied to the determination of seven volatile organic compounds (VOCs): chloroform, 1,1,1-trichloroethane, trichloroethylene, 1,1,2-trichloroethane, tetrachloroethene, 1,1,1,2-tetrachloroethane, 1,1,2,2-tetrachloroethane with boiling points between 61 and 147 degrees C in aqueous samples. Different from the known procedure the new, shortened membrane bags were filled with 100 microl of an organic solvent. The membrane bags were placed in a 20 ml headspace vial and filled with 15 ml of the aqueous sample. The vial was transferred into an autosampler where it was stirred for a definite time at elevated temperature. After the extraction, 1 microl of the organic extract was transferred into the spilt/splitless injector of a GC system equipped with an electron-capture detector. This work included optimization of the membrane device, the determination of the optimized extraction conditions such as stirring rate, extraction time and the impact of salt addition. The validation of the method involved repeatability, recovery and detection limit studies, followed of its application towards real water samples. The repeatability, expressed as the relative standard deviation of the peak areas of six extractions was below 10%. The detection limits (LODs) were between 5 ng/l (tetrachloroethene) and 50 ng/l (chloroform). Calibration was performed in a range from 5 ng/l to 150 microg/l, since the concentration in the aqueous samples was expected quite various in this concentration range. Five river water samples of Bitterfeld, Saxony-Anhalt, Germany were analyzed with miniaturized-MASE and the results were compared with those obtained with Headspace-Analysis. The method can be fully automated and moreover, it allows the simultaneous determination of volatile and semi volatile compounds.

PubMed Disclaimer

Publication types

MeSH terms

Substances

LinkOut - more resources