Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2005 Dec;29(12):1557-62.
doi: 10.1007/s00268-005-0106-x.

Effective radiation dose from radiologic studies in pediatric trauma patients

Affiliations

Effective radiation dose from radiologic studies in pediatric trauma patients

Patrick K Kim et al. World J Surg. 2005 Dec.

Abstract

Evaluation of the pediatric trauma patient frequently requires radiologic studies. Although low-dose radiation from diagnostic radiology is considered safe, lifetime risks per unit dose of radiation are increased in children compared to adults. The total effective dose of radiation to a typical pediatric trauma patient is unknown. We sought to estimate the total effective dose of radiation related to the radiologic assessment of injured children admitted to a pediatric Level I trauma center. We reviewed the radiology records of all children admitted directly to a trauma center in 2002 and tabulated all plain films, computed tomograms, angiographic/fluoroscopic studies, and nuclear medicine studies. Using age-adjusted effective doses (which incorporate biologic effects of radiation), we computed each patient's total effective dose of radiation. Of 506 admitted patients, 394 (78%) underwent at least one radiologic study. The mean total effective dose per patient was 14.9 mSv (median: 7.2 mSv; interquartile range: 2.2-27.4 mSv). On average, computed tomography accounted for 97.5% of total effective dose. Age and injury severity score did not predict total effective dose. We conclude that in pediatric trauma patients, the estimated total effective dose of radiation varied widely. Computed tomography contributed virtually the entire total effective dose. Regarding radiographic evaluation of pediatric trauma patients, the risks and benefits of current practices should continue to be evaluated critically, because lifetime risks associated with radiation exposure are inversely proportional to age at exposure.

PubMed Disclaimer

References

    1. Radiology. 2002 Apr;223(1):5-6 - PubMed
    1. Pediatr Pulmonol. 1998 Dec;26(6):389-95 - PubMed
    1. Pediatrics. 1988 Jul;82(1):11-5 - PubMed
    1. Br J Radiol. 2003 Nov;76(911):803-11 - PubMed
    1. AJR Am J Roentgenol. 2001 Feb;176(2):289-96 - PubMed

LinkOut - more resources