Nonenzymatic direct assay of hydrogen peroxide at neutral pH using the Eu3Tc fluorescent probe
- PMID: 16341794
- DOI: 10.1007/s10895-005-2984-6
Nonenzymatic direct assay of hydrogen peroxide at neutral pH using the Eu3Tc fluorescent probe
Abstract
A detailed study is presented on the use of an easily accessible probe (the europium-tetracycline 3:1 complex; referred to as Eu3Tc) for determination of hydrogen peroxide (HP). Eu3Tc undergoes a 15-fold increase in luminescence intensity on exposure to an excess of HP. Data are given on the time dependence of the reaction, on the pH dependence of the absorption and emission spectra of both the probe and its complex with HP, and on the effect of stoichiometry between Eu3+ and Tc on selectivity and signal change. HP can be quantified in aqueous solution of pH 6.9 over a 2-400 microM concentration range with a limit of detection of 960 nM. The assay is validated using standard additions, and mean recoveries are found to be between 97.0 and 101.8%. Species that interfere in concentrations below 1 mM include phosphate, copper(II), fluoride and citrate. The addition of detergents causes the response curves towards HP to shift to higher HP concentrations. The method is critically assessed with respect to other common optical methods for determination of HP.
Similar articles
-
NO fluorescence sensing by europium tetracyclines complexes in the presence of H2O2.J Fluoresc. 2013 Jul;23(4):681-8. doi: 10.1007/s10895-013-1207-9. Epub 2013 Mar 8. J Fluoresc. 2013. PMID: 23471628
-
A novel method for time-resolved fluorimetric determination and imaging of the activity of peroxidase, and its application to an enzyme-linked immunosorbent assay.Chemistry. 2006 Mar 20;12(10):2730-8. doi: 10.1002/chem.200500884. Chemistry. 2006. PMID: 16416495
-
Spectrofluorimetric determination of heparin using a tetracycline-europium probe.Anal Biochem. 2005 Jun 15;341(2):299-307. doi: 10.1016/j.ab.2005.03.014. Anal Biochem. 2005. PMID: 15907876
-
Time-resolved luminescence imaging of hydrogen peroxide using sensor membranes in a microwell format.Appl Spectrosc. 2003 Nov;57(11):1386-92. doi: 10.1366/000370203322554554. Appl Spectrosc. 2003. PMID: 14658153
-
Time-resolved fluorescent imaging of glucose.J Fluoresc. 2004 Sep;14(5):561-8. doi: 10.1023/b:jofl.0000039343.02843.12. J Fluoresc. 2004. PMID: 15617263
Cited by
-
NO fluorescence sensing by europium tetracyclines complexes in the presence of H2O2.J Fluoresc. 2013 Jul;23(4):681-8. doi: 10.1007/s10895-013-1207-9. Epub 2013 Mar 8. J Fluoresc. 2013. PMID: 23471628
-
Luminescent and Chiroptical Properties of 1 : 1 Eu (III) : Tetracycline Species Probed by Circularly Polarized Luminescence.Chempluschem. 2019 Dec;84(12):1796-1804. doi: 10.1002/cplu.201900627. Epub 2019 Nov 22. Chempluschem. 2019. PMID: 31943861 Free PMC article.
-
Challenges and Opportunities for Small-Molecule Fluorescent Probes in Redox Biology Applications.Antioxid Redox Signal. 2018 Aug 20;29(6):518-540. doi: 10.1089/ars.2017.7491. Epub 2018 Feb 16. Antioxid Redox Signal. 2018. PMID: 29320869 Free PMC article. Review.
-
Lanthanide probes for bioresponsive imaging.Chem Rev. 2014 Apr 23;114(8):4496-539. doi: 10.1021/cr400477t. Epub 2013 Dec 13. Chem Rev. 2014. PMID: 24328202 Free PMC article. Review. No abstract available.
-
Investigation of the europium emission spectra of the europium-oxytetracycline complex in the presence of human low-density lipoproteins.J Fluoresc. 2011 May;21(3):887-92. doi: 10.1007/s10895-010-0602-8. Epub 2010 Feb 23. J Fluoresc. 2011. PMID: 20177749
References
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Research Materials
Miscellaneous