An in vitro biomechanical comparison of a limited-contact dynamic compression plate fixation with a dynamic compression plate fixation of osteotomized equine third metacarpal bones
- PMID: 16343145
- DOI: 10.1111/j.1532-950X.2005.00092.x
An in vitro biomechanical comparison of a limited-contact dynamic compression plate fixation with a dynamic compression plate fixation of osteotomized equine third metacarpal bones
Abstract
Objectives: To compare the monotonic biomechanical properties and fatigue life of a broad, limited contact, dynamic compression plate (LC-DCP) fixation with a broad, dynamic compression plate (DCP) fixation to repair osteotomized equine 3rd metacarpal (MC3) bones.
Study design: In vitro biomechanical testing of paired cadaveric equine MC3 with a mid-diaphyseal osteotomy, stabilized by 1 of 2 methods for fracture fixation.
Animal population: Twelve pairs of adult equine cadaveric MC3 bones.
Methods: Twelve pairs of equine MC3 were divided into 3 test groups (4 pairs each) for (1) 4-point bending single cycle to failure testing, (2) 4-point bending cyclic fatigue testing, and (3) torsional single cycle to failure testing. An LC-DCP (8-hole, 4.5 mm) was applied to the dorsal surface of 1 randomly selected bone from each pair. One DCP (8-hole, 4.5 mm broad) was applied dorsally to the contralateral bone from each pair. All plates and screws were applied using standard AO/ASIF techniques to MC3 bones that had mid-diaphyseal osteotomies. Mean test variable values for each method were compared using a paired t-test within each group. Significance was set at P<.05.
Results: The mean 4-point bending yield load, yield bending moment, composite rigidity, failure load, and failure bending moment of LC-DCP fixation were significantly greater (P<.01) than those of broad DCP fixation. Mean cycles to failure for 4-point bending was significantly (P<.001) greater for broad DCP fixation compared with broad LC-DCP fixation. Mean yield load, mean composite rigidity, and mean failure load in torsion was significantly (P<.02) greater for broad LC-DCP fixation compared with broad DCP fixation.
Conclusion: Broad LC-DCP offers increased stability in static overload testing, however, it offers significantly less stability in cyclic fatigue testing.
Clinical relevance: The clinical relevance of the cyclic fatigue data supports the conclusion that the broad DCP fixation is biomechanically superior to the broad LC-DCP fixation in osteotomized equine MC3 bones despite the results of the static overload testing.
Similar articles
-
An in vitro biomechanical comparison of a prototype equine metacarpal dynamic compression plate fixation with double dynamic compression plate fixation of osteotomized equine third metacarpal bones.Vet Surg. 2005 Nov-Dec;34(6):594-603. doi: 10.1111/j.1532-950X.2005.00093.x. Vet Surg. 2005. PMID: 16343147
-
An in vitro evaluation of plate luting using osteotomized equine third metacarpal bones with a limited contact-dynamic compression plate.Vet Surg. 2005 Nov-Dec;34(6):587-93. doi: 10.1111/j.1532-950X.2005.00091.x. Vet Surg. 2005. PMID: 16343146
-
An in vitro biomechanical comparison of a 5.5 mm limited-contact dynamic compression plate fixation with a 4.5 mm limited-contact dynamic compression plate fixation of osteotomized equine third metacarpal bones.Vet Surg. 2008 Apr;37(3):289-93. doi: 10.1111/j.1532-950X.2008.00379.x. Vet Surg. 2008. PMID: 18394077
-
[Limited Contact Dynamic Compression Plate (LC-DCP)--biomechanical research as basis to new plate design].Orthopade. 1992 Feb;21(1):11-23. Orthopade. 1992. PMID: 1549332 Review. German.
-
Meta-bone Fracture Repair via Minimally Invasive Plate Osteosynthesis.Vet Clin North Am Small Anim Pract. 2020 Jan;50(1):207-212. doi: 10.1016/j.cvsm.2019.08.011. Epub 2019 Oct 21. Vet Clin North Am Small Anim Pract. 2020. PMID: 31648818 Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous