. 2005 Dec;165(22):2639-43.
doi: 10.1001/archinte.165.22.2639.

Outbreak of catheter-associated Klebsiella oxytoca and Enterobacter cloacae bloodstream infections in an oncology chemotherapy center

Affiliations

Outbreak of catheter-associated Klebsiella oxytoca and Enterobacter cloacae bloodstream infections in an oncology chemotherapy center

John T Watson et al. Arch Intern Med. 2005 Dec.

Abstract

Background: In March 2004, the Chicago Department of Public Health was notified of a cluster of bloodstream infections with Klebsiella oxytoca and Enterobacter cloacae at a chemotherapy center. Our purpose was to identify the source of the outbreak and prevent further cases.

Methods: The investigation included 103 oncology patients seen at an outpatient oncology chemotherapy center in Chicago during the 16 days before its closure. The outbreak investigation included case identification, retrospective cohort study, review of medical records, microbiologic testing of blood specimens, environmental cultures, and pulsed-field gel electrophoresis. The main outcome measure was infection with K oxytoca, E cloacae, or both, and the Mantel-Haenszel chi(2) test was used to assess risk of infection in relation to presence of central venous catheter.

Results: Among the 103 patients, risk of infection was associated with the presence of central venous catheter (relative risk undefined, P<.001). Twenty-seven patients had blood cultures that grew K oxytoca, E cloacae, or both, and all had central venous catheters that were flushed with isotonic sodium chloride solution at the clinic from February 17 through March 3, 2004. Isolates of K oxytoca and E cloacae were matched by pulsed-field gel electrophoresis to K oxytoca and E cloacae isolates obtained from multiple predrawn syringes and from the intravenous fluid and administration set in use in the clinic at the time of its closing.

Conclusions: The injection of contaminated isotonic sodium chloride solution through the venous catheters of attendees at the clinic likely provided the opportunity for bloodstream infections in these 27 case patients. This outbreak highlights the need for continued emphasis on safe injection practices and suggests the need for guidelines and recommendations tailored to outpatient settings.