[Reliability of porous coating metal-backed cups: advantages and adverse effect of a posterior elevated rim polyethylene liner]
- PMID: 16351000
- DOI: 10.1016/s0035-1040(05)84360-0
[Reliability of porous coating metal-backed cups: advantages and adverse effect of a posterior elevated rim polyethylene liner]
Abstract
Purpose of the study: We analyzed primary implantation of the Duraloc cup associated with a self-locking Muller stem at 9.6 +/- 1.6 years (8.6-11.4). Because of its particular 3/5 semi-spherical shape, the Duraloc cup has been associated with a high rate of dislocation. The objective of this study was to evaluate the efficacy of an anti-dislocation posterior elevated rim polyethylene liner on long-term dislocation rate and wear.
Material and methods: The series included 89 arthroplasties implanted between 1991 and 1993 in 82 patients, mean age 56.8 +/- 12.6 years (17.2-87). The Postel-Merle-d'Aubligné (PMA) score and subjective evaluation with a visual analog scale were used for the clinical assessment. Changes in the bone-cup interface, cup migration, and polyethylene wear were assessed radiographically.
Results: At last follow-up, the PMA function score was 16.2 +/- 1.9 points (10-18) (81% good, very good and excellent results). The postoperative x-rays showed a low incidence of lucent lines and osteolysis, respectively 8% and 4%. Mean annual linear polyethylene wear was 0.11 +/- 0.066 mm (0.03-0.57) and only 4% of the cups showed wear greater than 0.2 mm/year. Wear was correlated with the presence of acetabular osteolysis and high activity level. Two cups migrated (3-4 cm medialization). Three cups were revised, one for deep infection, one for recurrent dislocation, and one for dislocation associated with major wear. The rate of dislocation was 2.2% (two cases). Overall survival was 97.3% at 9.6 years (95%CI 0.93-1.0).
Discussion: Compared with other series in the literature using this implant, the presence of a posterior elevated rim polyethylene liner reduced the rate of instability and did not increase wear. The Duraloc cup is recognized as a reliable implant exhibiting excellent osteointegration and a low rate of migration. The presence of a posterior rim is associated with a lower rate of dislocation and does not increase wear. It can thus be proposed for primary implantation. The posterosuperior position for the liner is recommended.
Similar articles
-
Correlation of Cup Inclination Angle with Liner Wear for Metal-on-polyethylene in Hip Primary Arthroplasty.Orthop Surg. 2017 May;9(2):186-190. doi: 10.1111/os.12337. Epub 2017 May 30. Orthop Surg. 2017. PMID: 28557297 Free PMC article.
-
[The cementless Duraloc acetabular component: 100 cases assessed after a minimum five year follow-up].Rev Chir Orthop Reparatrice Appar Mot. 2004 Sep;90(5):434-41. doi: 10.1016/s0035-1040(04)70170-1. Rev Chir Orthop Reparatrice Appar Mot. 2004. PMID: 15502766 French.
-
[Long-term results of the CLS acetabular cup in primary total hip replacement].Acta Chir Orthop Traumatol Cech. 2009 Apr;76(2):90-7. Acta Chir Orthop Traumatol Cech. 2009. PMID: 19439127 Czech.
-
[Results of the Evora dual mobility socket: five years follow-up].Rev Chir Orthop Reparatrice Appar Mot. 2008 Feb;94(1):37-42. doi: 10.1016/j.rco.2007.10.009. Epub 2008 Feb 1. Rev Chir Orthop Reparatrice Appar Mot. 2008. PMID: 18342028 French.
-
Intra-prosthetic dislocation of dual-mobility cups after total hip arthroplasty: potential causes from a clinical and biomechanical perspective.Int Orthop. 2016 May;40(5):901-6. doi: 10.1007/s00264-015-3000-7. Epub 2015 Oct 1. Int Orthop. 2016. PMID: 26429197 Review.
Cited by
-
Migration of the Duraloc cup after 5 years.Int Orthop. 2008 Dec;32(6):791-4. doi: 10.1007/s00264-007-0405-y. Epub 2007 Jul 3. Int Orthop. 2008. PMID: 17609953 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Research Materials