Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2005 Nov-Dec;15(10):1379-83.
doi: 10.1381/096089205774859254.

Increased burst pressure in gastrointestinal staple-lines using reinforcement with a bioprosthetic material

Affiliations

Increased burst pressure in gastrointestinal staple-lines using reinforcement with a bioprosthetic material

Douglas M Downey et al. Obes Surg. 2005 Nov-Dec.

Abstract

Background: Leakage at an anastomosis is a major and often catastrophic complication of gastrointestinal (GI) surgery. Staple-line reinforcement with one of the several materials commercially available has been utilized to reduce the incidence of this complication. The bioprosthetic material, small intestinal submucosa (SIS, Surgisis((R)); Cook, Inc., Bloomington, IN) has found widespread applications in surgery. However, its ability to improve the durability of staple-lines in GI surgery in terms of burst pressure has not been documented. We hypothesized that SIS reinforcement of staple-lines in healthy living GI tissue would increase durability, as determined by leak rates at increased intraluminal pressures, compared to unreinforced staple-lines.

Methods: Two healthy Yorkshire-Cross pigs were subjected to midline laparotomy and underwent small intestinal division (n=28) with GIA stapling devices. Half of the staple-lines were reinforced with SIS. The staple-lines were then exposed to increased intraluminal pressures by means of a constant-rate dye solution infusion, until staple-lines exhibited visible leakage of the dye solution. The intraluminal pressure was recorded at the time of visible leakage.

Results: Staple-lines reinforced with SIS had significantly better durability as determined by analysis of variance and Kaplan-Meier survival calculations, with respect to leak rate as a function of intraluminal pressure (P<0.003). The mean burst pressure of the unreinforced staple-lines was 53 mmHg, while those staple-lines reinforced with SIS had a mean burst pressure of 83 mmHg.

Conclusion: Reinforcement of stapled GI anastomoses with SIS significantly increases anastomotic burst pressure. These findings suggest a role for this material in GI surgery.

PubMed Disclaimer

LinkOut - more resources