Rapid dual-tracer PTSM+ATSM PET imaging of tumour blood flow and hypoxia: a simulation study
- PMID: 16357431
- DOI: 10.1088/0031-9155/51/1/005
Rapid dual-tracer PTSM+ATSM PET imaging of tumour blood flow and hypoxia: a simulation study
Abstract
Blood flow and hypoxia are interrelated aspects of physiology that affect cancer treatment and response. Cu-PTSM and Cu-ATSM are related PET tracers for blood flow and hypoxia, and the ability to rapidly image both tracers in a single scan would bring several advantages over conventional single-tracer techniques. Using dynamic imaging with staggered injections, overlapping signals for multiple PET tracers may be recovered utilizing information from kinetics and radioactive decay. In this work, rapid dual-tracer PTSM+ATSM PET was simulated and tested as a function of injection delay, order and relative dose for several copper isotopes, and the results were compared relative to separate single-tracer data. Time-activity curves representing a broad range of tumour blood flow and hypoxia levels were simulated, and parallel dual-tracer compartment modelling was used to recover the signals for each tracer. The main results were tested further using a torso phantom simulation of PET tumour imaging. Using scans as short as 30 minutes, the dual-tracer method provided measures of blood flow and hypoxia similar to single-tracer imaging. The best performance was obtained by injecting PTSM first and using a somewhat higher dose for ATSM. Comparable results for different copper isotopes suggest that tracer kinetics with staggered injections play a more important role than radioactive decay in the signal separation process. Rapid PTSM+ATSM PET has excellent potential for characterizing both tumour blood flow and hypoxia in a single, fast scan, provided that technological hurdles related to algorithm development and routine use can be overcome.
Similar articles
-
Evaluation of rapid dual-tracer (62)Cu-PTSM + (62)Cu-ATSM PET in dogs with spontaneously occurring tumors.Phys Med Biol. 2008 Jan 7;53(1):217-32. doi: 10.1088/0031-9155/53/1/015. Epub 2007 Dec 19. Phys Med Biol. 2008. PMID: 18182698 Free PMC article.
-
PET with 62Cu-ATSM and 62Cu-PTSM is a useful imaging tool for hypoxia and perfusion in pulmonary lesions.AJR Am J Roentgenol. 2013 Nov;201(5):W698-706. doi: 10.2214/AJR.12.9698. AJR Am J Roentgenol. 2013. PMID: 24147499 Free PMC article.
-
Monitoring the effect of mild hyperthermia on tumour hypoxia by Cu-ATSM PET scanning.Int J Hyperthermia. 2006 Mar;22(2):93-115. doi: 10.1080/02656730600594191. Int J Hyperthermia. 2006. PMID: 16754595
-
PET imaging of tumour hypoxia.Cancer Imaging. 2006 Oct 31;6(Spec No A):S117-21. doi: 10.1102/1470-7330.2006.9018. Cancer Imaging. 2006. Retraction in: Cancer Imaging. 2007 Jan 17;7:1. doi: 10.1102/1470-7330.2007.0001. PMID: 17114063 Free PMC article. Retracted. Review.
-
Contribution of [64Cu]-ATSM PET in molecular imaging of tumour hypoxia compared to classical [18F]-MISO--a selected review.Nucl Med Rev Cent East Eur. 2011;14(2):90-5. doi: 10.5603/nmr.2011.00022. Nucl Med Rev Cent East Eur. 2011. PMID: 22219149 Review.
Cited by
-
Direct reconstruction for simultaneous dual-tracer PET imaging based on multi-task learning.EJNMMI Res. 2023 Jan 31;13(1):7. doi: 10.1186/s13550-023-00955-w. EJNMMI Res. 2023. PMID: 36719532 Free PMC article.
-
Kinetic modeling in PET imaging of hypoxia.Am J Nucl Med Mol Imaging. 2014 Sep 6;4(6):490-506. eCollection 2014. Am J Nucl Med Mol Imaging. 2014. PMID: 25250200 Free PMC article. Review.
-
Vasomodulation of tumor blood flow: effect on perfusion and thermal ablation size.Ann Biomed Eng. 2009 Mar;37(3):552-64. doi: 10.1007/s10439-008-9605-x. Epub 2008 Dec 16. Ann Biomed Eng. 2009. PMID: 19085107 Free PMC article.
-
Application of separable parameter space techniques to multi-tracer PET compartment modeling.Phys Med Biol. 2016 Feb 7;61(3):1238-58. doi: 10.1088/0031-9155/61/3/1238. Epub 2016 Jan 20. Phys Med Biol. 2016. PMID: 26788888 Free PMC article.
-
Quantitation of multiple injection dynamic PET scans: an investigation of the benefits of pooling data from separate scans when mapping kinetics.Phys Med Biol. 2021 Jul 1;66(13):10.1088/1361-6560/ac0683. doi: 10.1088/1361-6560/ac0683. Phys Med Biol. 2021. PMID: 34049293 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources