Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2005 Nov-Dec;49(6):448-452.
doi: 10.1007/s10384-005-0245-5.

Properties of corneas reconstructed with cultured human corneal endothelial cells and human corneal stroma

Affiliations
Comparative Study

Properties of corneas reconstructed with cultured human corneal endothelial cells and human corneal stroma

Shiro Amano et al. Jpn J Ophthalmol. 2005 Nov-Dec.

Abstract

Purpose: To examine the properties of corneas tissue-engineered with cultured human corneal endothelial cells (HCEC) and human corneal stroma.

Methods: Primary HCEC cultures were established from endothelial cell layer explants and propagated on culture dishes coated with bovine corneal endothelial extracellular matrix. A cell suspension of HCEC at the fifth passage was transferred onto human corneal stroma deprived of endothelial cells, and the corneas were gently centrifuged to enhance cell attachment. The cell density of the tissue-engineered corneas was examined after staining with alizarin red and trypan blue. The tissue-engineered corneas were histologically examined by light and electron microscopy. The pump function of the tissue-engineered corneas was measured using an Ussing chamber.

Results: The mean endothelial cell density of four tissue-engineered corneas was 2380 +/- 264 cells/mm(2) (mean +/- SD). HCEC on the tissue-engineered corneas had a morphology similar to HCEC in vivo. The pump function parameters of the tissue-engineered corneas were 55%-75% of those of normal corneas.

Conclusions: HCEC on the tissue-engineered corneas have morphology and cellular density similar to HCEC in vivo, whereas the pump function of the tissue-engineered corneas was lower than in normal corneas.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Cornea. 1999 Mar;18(2):207-13 - PubMed
    1. In Vitro Cell Dev Biol. 1989 Nov;25(11):1065-72 - PubMed
    1. Curr Eye Res. 1981;1(5):285-90 - PubMed
    1. Arch Ophthalmol. 1979 Nov;97(11):2163-9 - PubMed
    1. Cornea. 1991 Mar;10(2):136-48 - PubMed

Publication types

LinkOut - more resources