Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2006 Jan;23(1):40-1.
doi: 10.1136/emj.2004.022764.

An evaluation of tympanic thermometry in a paediatric emergency department

Affiliations

An evaluation of tympanic thermometry in a paediatric emergency department

A S El-Radhi et al. Emerg Med J. 2006 Jan.

Abstract

Background and objectives: The consequences of missing fever in children can be grave. Body temperature is commonly recorded at the axilla but accuracy is a problem. This study aimed to evaluate the accuracy of a tympanic thermometer in the paediatric emergency setting.

Method: In a total of 106 infants, the body temperature was measured in the daytime with an infrared tympanic thermometer, and at the axilla with an electronic thermometer and at the rectum (gold standard for measurement of body temperature). Fever was defined as a rectal temperature of 38.0 degrees C or greater, axillary temperature of 37.5 degrees C or greater, and tympanic temperature of 37.6 degrees C or greater. The temperature readings at the three sites were compared statistically.

Results: There was a greater correlation of the tympanic measurement with the rectal measurement than the axillary with the rectal in both febrile and afebrile infants. The mean difference between the tympanic and rectal measurements was lower than that between the axillary and rectal measurements in both groups of infants (tympanic 0.38 degrees C and 0.42 degrees C, and axillary 1.11 degrees C and 1.58 degrees C, respectively). Tympanic measurements had a sensitivity of 76% whereas axillary measurements had a sensitivity of only 24% with rectal temperatures of 38-38.9 degrees C.

Conclusion: Tympanic thermometry is more accurate than measurement of temperature with an electronic axillary thermometer. It is also quick and safe, and thus it is recommended in the paediatric emergency setting.

PubMed Disclaimer

Conflict of interest statement

Competing interests: none declared

Similar articles

Cited by

References

    1. Craig J V, Lancaster G A, Williamson P R.et al Temperature measured at the axilla compared with rectum in children and young people: systemic review. BMJ 20003201174–1178. - PMC - PubMed
    1. Greenes D S, Fleisher G R. When body temperature changes, does rectal temperature lag? J Pediatr 2004144824–826. - PubMed
    1. Kiernan B S. Ask the expert; taking a temperature: which way is best? J Soc Pediatr Nurs 20016192–195. - PubMed
    1. Robinson J L, Seal R F, Spady D W.et al Comparison of oesophageal, rectal, axillary, bladder, tympanic and pulmonary artery temperatures in children. J Pediatr 1998133553–556. - PubMed
    1. Craig J V, Lancaster G A, Taylor S.et al Infrared ear thermometry compared with rectal thermometry in children: a systematic review. Lancet 2002360603–609. - PubMed

Publication types