Continuous monitoring of analyte concentrations
- PMID: 1637523
- DOI: 10.1016/0956-5663(92)90015-f
Continuous monitoring of analyte concentrations
Abstract
We have investigated the application of a modified, heterogeneous, competitive enzyme immunoassay for the continuous measurement of small analytes in a medium stream. The analytical system contains two antibodies that are immobilized on spatially separated areas, one binding the analyte (Ab1) and the other binding the enzyme (Ab2). An analyte-enzyme conjugate serves as signal generator. The analyte-enzyme conjugate functions as a heterobifunctional shuttle that can bind to either antibody. A semipermeable membrane retains the enzyme shuttle in the internal volume of the sensor but permits the passage of small analytes from the medium stream. The amount of enzyme bound to Ab1 is inversely proportional and the amount of enzyme bound to Ab2 is directly proportional to the analyte concentration. We have demonstrated that this analytical system (1) can provide a larger total signal; (2) has a sensitivity comparable with conventional competitive immunoassays; (3) does not require the separation of bound from free antigens; and (4) is therefore suitable for the continuous measurement of analytes in a medium stream. With a model system, an increase from 0 ng ml-1 to 20 ng ml-1 of the steroid hormone progesterone and the subsequent fall to 0 ng ml-1 could be monitored.
Similar articles
-
Performance characteristics of a reversible immunosensor with a heterobifunctional enzyme conjugate as signal generator.Biotechnol Bioeng. 1997 Oct 20;56(2):221-31. doi: 10.1002/(SICI)1097-0290(19971020)56:2<221::AID-BIT11>3.0.CO;2-J. Biotechnol Bioeng. 1997. PMID: 18636627
-
Modeling of immunosensors under nonequilibrium conditions. II. Experimental determination of performance characteristics.Anal Biochem. 1991 Aug 1;196(2):326-36. doi: 10.1016/0003-2697(91)90474-8. Anal Biochem. 1991. PMID: 1776682
-
Irreversible enzyme-shuttle immunoassay.Biotechnol Bioeng. 1992 Mar 25;39(7):753-64. doi: 10.1002/bit.260390708. Biotechnol Bioeng. 1992. PMID: 18601007
-
Enzyme modulator mediated immunoassay (EMMIA).Int J Biochem. 1983;15(5):583-90. doi: 10.1016/0020-711x(83)90180-5. Int J Biochem. 1983. PMID: 6345231 Review.
-
Enzyme immunoassay techniques. An overview.J Immunol Methods. 1992 Jun 24;150(1-2):5-21. doi: 10.1016/0022-1759(92)90061-w. J Immunol Methods. 1992. PMID: 1613258 Review.
Cited by
-
Antigen-antibody binding kinetics for biosensors. Changes in the fractal dimension (surface roughness) and in the binding rate coefficient.Appl Biochem Biotechnol. 1996 Aug;60(2):123-38. doi: 10.1007/BF02788067. Appl Biochem Biotechnol. 1996. PMID: 8856941 Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources