Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2005 Oct-Dec;51(4):260-4; discussion 264-5.

Opioid sparing during endotracheal intubation using McCoy laryngoscope in neurosurgical patients: the comparison of haemodynamic changes with Macintosh blade in a randomized trial

Affiliations
  • PMID: 16388166
Randomized Controlled Trial

Opioid sparing during endotracheal intubation using McCoy laryngoscope in neurosurgical patients: the comparison of haemodynamic changes with Macintosh blade in a randomized trial

Prabhat Tewari et al. J Postgrad Med. 2005 Oct-Dec.

Abstract

Background: There is conflicting data in literature to show that the McCoy laryngoscope is less stressful and opioids can actually be avoided during laryngoscopy and intubation with the use of this laryngoscope.

Aim: A comparison of hemodynamic changes with McCoy vs Macintosh laryngoscope..

Settings and design: 180 ASA I and II neurosurgical patients undergoing elective surgery for space occupying lesions were recruited. The study was was prospective, randomized and blinded in the setting of neurosurgical perioperative services.

Methods and materials: The patients were divided into four groups (Gr.1 McCoy and fentanyl; Gr. 2 McCoy and no fentanyl; Gr. 3 Macintosh and fentanyl; Gr. 4 Macintosh and no fentanyl). In Gr. 2 and 4 equivalent volume of saline was given in place of fentanyl as placebo. Heart rate, systolic and diastolic blood pressure were measured after laryngoscopy, after intubation and subsequently every minute for the next five minutes. The incidence of cough due to fentanyl treatment was observed.

Statistical analysis: Haemodynamic changes were compared between and within groups using oneway ANOVA and repeated measures ANOVA. All analysis included 95% CI at 5% significance. The Mann Whitney U test was used for comparing incidence of cough.

Results: No difference was found between McCoy laryngoscopy when done with or without fentanyl pretreatment (HR p=0.848, sys BP p=0.229 and diastolic blood pressure p=0.981). Significant changes in haemodynamic parameters were seen between Macintosh and McCoy laryngoscopy without fentanyl pretreatment (p<0.001) whereas changes were blunted with fentanyl pretreatment in Macintosh laryngoscopy (p<0.05).

Conclusions: McCoy laryngoscope blade is less stressful and fentanyl pretreatment is not necessary to attenuate haemodynamic responses with its use in ASA I and II patients.

PubMed Disclaimer

Publication types

LinkOut - more resources