Experimental method for determining the damping parameter of spectral lines emitted by a microwave plasma at atmospheric pressure
- PMID: 16390583
- DOI: 10.1366/000370205775142584
Experimental method for determining the damping parameter of spectral lines emitted by a microwave plasma at atmospheric pressure
Abstract
In this work, a simple method for experimentally obtaining the value of the damping parameter or a-parameter of the spectral lines emitted by an argon plasma generated at atmospheric pressure is presented. The value of this coefficient indicates the proportion existing between the Lorentzian and Doppler components of the total line profile, which can be approximated to a Voigt function for our experimental conditions. The a-parameter values found were within the value interval recorded in the literature. The results obtained showed that the damping coefficient of the lines next to the fundamental level remains practically constant along the plasma column, whereas for the spectral lines involving high-lying levels, the a-parameter is sensitive to the changes in the electron density in the plasma. In this work it is also proved that the self-absorption phenomenon induces errors in the calculation of a, due to an increase in the broadening of the line profile produced by this phenomenon.
Similar articles
-
Abel inversion applied to a small set of emission data from a microwave plasma.Appl Spectrosc. 2006 Mar;60(3):229-36. doi: 10.1366/000370206776342706. Appl Spectrosc. 2006. PMID: 16608564
-
Resonant laser ablation of metals detected by atomic emission in a microwave plasma and by inductively coupled plasma mass spectrometry.Appl Spectrosc. 2005 Dec;59(12):1427-44. doi: 10.1366/000370205775142656. Appl Spectrosc. 2005. PMID: 16390581
-
[Effects of gas composition and pressure on the intensity and quality of the plasma induced by a high-energy neodymium glass laser].Guang Pu Xue Yu Guang Pu Fen Xi. 2005 Mar;25(3):341-5. Guang Pu Xue Yu Guang Pu Fen Xi. 2005. PMID: 16013302 Chinese.
-
Determination of phosphorus, sulfur and the halogens using high-temperature molecular absorption spectrometry in flames and furnaces--A review.Anal Chim Acta. 2009 Aug 11;647(2):137-48. doi: 10.1016/j.aca.2009.06.029. Epub 2009 Jun 21. Anal Chim Acta. 2009. PMID: 19591698 Review.
-
Evaluation of methods for trace-element determination with emphasis on their usability in the clinical routine laboratory.Scand J Clin Lab Invest. 2007;67(4):353-66. doi: 10.1080/00365510601095281. Scand J Clin Lab Invest. 2007. PMID: 17558890 Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources