Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2006 Mar;36(3):219-23.
doi: 10.1007/s00247-005-0058-1. Epub 2006 Jan 4.

Evaluation of obstructive airway lesions in complex congenital heart disease using composite volume-rendered images from multislice CT

Affiliations

Evaluation of obstructive airway lesions in complex congenital heart disease using composite volume-rendered images from multislice CT

Ki Seok Choo et al. Pediatr Radiol. 2006 Mar.

Abstract

Background: Multislice CT (MSCT) allows high-quality volume-rendered (VR) and composite volume-rendered images.

Objective: To investigate the clinical usefulness of composite VR images in the evaluation of the relationship between cardiovascular structures and the airway in children with complex congenital heart disease (CHD).

Materials and methods: Four- or 16-slice MSCT scanning was performed consecutively in 77 children (mean age 6.4 months) with CHD and respiratory symptoms, a chest radiographic abnormality, or abnormal course of the pulmonary artery on ECHO. MSCT scanning was performed during breathing or after sedation. Contrast medium (2 ml/kg) was administered through a pedal venous route or arm vein in all patients. The VR technique was used to reconstruct the cardiovascular structures and airway, and then both VR images were composed using the commercial software (VoxelPlus(2); Daejeon, Korea).

Results: Stenoses were seen in the trachea in 1 patient and in the bronchi in 14 patients (19%). Other patients with complex CHD did not have significant airway stenoses.

Conclusions: Composite VR images with MSCT can provide more exact airway images in relationship to the surrounding cardiovascular structures and thus help in optimizing management strategies in treating CHD.

PubMed Disclaimer

Similar articles

Cited by

References

    1. AJR Am J Roentgenol. 1996 Feb;166(2):293-9 - PubMed
    1. J Thorac Cardiovasc Surg. 1990 Jun;99(6):1091-8 - PubMed
    1. AJR Am J Roentgenol. 1996 Aug;167(2):419-24 - PubMed
    1. J Comput Assist Tomogr. 1994 Jul-Aug;18(4):552-4 - PubMed
    1. Pediatr Radiol. 1994;24(3):175-9 - PubMed