Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2006 Jan-Feb;27(1):13-18.
doi: 10.1007/s00246-005-0772-3.

Different responses in adult and neonatal hearts to changes in coronary perfusion pressure

Affiliations
Comparative Study

Different responses in adult and neonatal hearts to changes in coronary perfusion pressure

N Ishiyama et al. Pediatr Cardiol. 2006 Jan-Feb.

Abstract

The influence of coronary perfusion pressure on neonatal heart function has not been evaluated. We compared the coronary perfusion pressure-cardiac function relationship between neonatal and adult hearts. Neonatal and adult rabbit hearts were examined. The coronary perfusion pressure was changed in increments of 10 mmHg. Coronary blood flow and left ventricular functions were measured at each coronary perfusion pressure. Autoregulatory capacity for coronary blood flow was quantified by calculating the autoregulation index. In neonatal hearts, left ventricular developed pressure was decreased at high perfusion pressure, whereas in adult hearts left ventricular developed pressure increased at high perfusion pressure. In neonatal hearts, left ventricular enddiastolic pressure was elevated at both low and high perfusion pressure, whereas in adult hearts left ventricular enddiastolic pressure remained constant at all perfusion pressures. Adult hearts exhibited coronary blood flow autoregulation in the perfusion pressure range between 40 and 90 mmHg. In contrast, neonatal hearts did not show autoregulation in any perfusion pressure range. In neonatal hearts, both low and high perfusion pressure caused deterioration in ventricular function attributable to the immaturity of coronary autoregulatory capacity. We conclude that coronary perfusion pressure should be controlled within a narrow range for neonates.

PubMed Disclaimer

Similar articles

References

    1. Circ Res. 1980 Apr;46(4):503-12 - PubMed
    1. Circulation. 1996 Nov 1;94(9 Suppl):II326-31 - PubMed
    1. Circ Res. 1960 Jul;8:794-800 - PubMed
    1. Cardiovasc Res. 1994 Mar;28(3):414-9 - PubMed
    1. Pediatr Int. 2000 Feb;42(1):26-30 - PubMed

Publication types

LinkOut - more resources