High-dose senna compared with conventional PEG-ES lavage as bowel preparation for elective colonoscopy: a prospective, randomized, investigator-blinded trial
- PMID: 16393219
- DOI: 10.1111/j.1572-0241.2005.00335.x
High-dose senna compared with conventional PEG-ES lavage as bowel preparation for elective colonoscopy: a prospective, randomized, investigator-blinded trial
Abstract
Objective: To compare the efficacy and patient acceptance of an oral high dose of senna to conventional polyethylene glycol-electrolyte lavage solution (PEG-ES) in adults undergoing elective colonoscopy.
Methods: Consecutive outpatients referred for elective colonoscopy were prospectively randomly assigned to receive, the day before the procedure, either 24 tablets of 12 mg senna, divided into two doses at 1 p.m. and 9 p.m. (senna group, n=191), or standard 4-L PEG-ES (PEG-ES group, n=92). The overall quality of colon cleansing (primary outcome measure) and cleansing in the right colon were evaluated using the Aronchick scoring scale (1=excellent to 4=inadequate) by the investigator/endoscopist who was blinded to the treatment assignment. Patient acceptance and the safety of the preparation were assessed by a nurse, using a structured questionnaire covering compliance with the dosing, overall tolerance of the preparation (1=none or mild discomfort to 4=severely distressing), and adverse events.
Results: The quality of colon cleansing, overall tolerance of the preparation, and compliance were significantly better with senna; overall cleansing was excellent or good in 90.6% of patients in the senna group and in 79.7% in the PEG-ES group (p= 0.003). The percentage of procedures rescheduled because of insufficient colon cleansing was 7.3% in the PEG-ES group and 2.6% in the senna group (p=0.035). Multivariate logistic regression modeling showed the PEG-ES preparation as negative independent predictor of unsuccessful bowel cleansing. The incidence of adverse reactions was similar in the two groups; patients who received senna experienced significantly less nausea and vomiting, but more abdominal pain.
Conclusions: An oral high dose of senna is a valid alternative to standard PEG-ES for outpatient colonoscopy preparation.
Similar articles
-
Half doses of PEG-ES and senna vs. high-dose senna for bowel cleansing before colonoscopy: a randomized, investigator-blinded trial.Am J Gastroenterol. 2010 Mar;105(3):675-81. doi: 10.1038/ajg.2009.598. Epub 2009 Oct 20. Am J Gastroenterol. 2010. PMID: 19844199 Clinical Trial.
-
Administration of olive oil followed by a low volume of polyethylene glycol-electrolyte lavage solution improves patient satisfaction with right-side colonic cleansing over administration of the conventional volume of polyethylene glycol-electrolyte lavage solution for colonoscopy preparation.Gastrointest Endosc. 2009 Sep;70(3):515-21. doi: 10.1016/j.gie.2009.01.002. Epub 2009 Jun 24. Gastrointest Endosc. 2009. PMID: 19555936 Clinical Trial.
-
A randomized, controlled, double-blind trial of the adjunct use of tegaserod in whole-dose or split-dose polyethylene glycol electrolyte solution for colonoscopy preparation.Gastrointest Endosc. 2008 Aug;68(2):294-300; quiz 334, 336. doi: 10.1016/j.gie.2008.01.044. Epub 2008 Jun 3. Gastrointest Endosc. 2008. PMID: 18511049 Clinical Trial.
-
Bowel preparation before colonoscopy in the era of mass screening for colo-rectal cancer: a practical approach.Dig Liver Dis. 2009 Feb;41(2):87-95. doi: 10.1016/j.dld.2008.06.005. Epub 2008 Jul 26. Dig Liver Dis. 2009. PMID: 18676211 Review.
-
Which is the optimal bowel preparation for colonoscopy - a meta-analysis.Colorectal Dis. 2006 May;8(4):247-58. doi: 10.1111/j.1463-1318.2006.00970.x. Colorectal Dis. 2006. PMID: 16630226 Review.
Cited by
-
Safety of Polyethylene Glycol Solution plus Ascorbic Acid for Bowel Preparation for Colonoscopy in Patients with Chronic Kidney Disease.Gastroenterol Res Pract. 2021 Mar 15;2021:6696591. doi: 10.1155/2021/6696591. eCollection 2021. Gastroenterol Res Pract. 2021. PMID: 33815499 Free PMC article.
-
The Efficacy and Safety of Combined Senna and Probiotic-Based Bowel Preparation for Colonoscopy in Children.Cureus. 2020 Sep 1;12(9):e10180. doi: 10.7759/cureus.10180. Cureus. 2020. PMID: 33029460 Free PMC article.
-
Is senna laxative use associated to cathartic colon, genotoxicity, or carcinogenicity?J Toxicol. 2009;2009:287247. doi: 10.1155/2009/287247. Epub 2009 Sep 10. J Toxicol. 2009. PMID: 20107583 Free PMC article.
-
Combination could be another tool for bowel preparation?World J Gastroenterol. 2016 Mar 14;22(10):2915-21. doi: 10.3748/wjg.v22.i10.2915. World J Gastroenterol. 2016. PMID: 26973388 Free PMC article. Review.
-
Predictive factors for inadequate bowel preparation using low-volume polyethylene glycol (PEG) plus ascorbic acid for an outpatient colonoscopy.Sci Rep. 2019 Dec 23;9(1):19715. doi: 10.1038/s41598-019-56107-5. Sci Rep. 2019. PMID: 31873135 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical