An objective spinal motion imaging assessment (OSMIA): reliability, accuracy and exposure data

Affiliations

An objective spinal motion imaging assessment (OSMIA): reliability, accuracy and exposure data

Alan C Breen et al. BMC Musculoskelet Disord. .

Abstract

Background: Minimally-invasive measurement of continuous inter-vertebral motion in clinical settings is difficult to achieve. This paper describes the reliability, validity and radiation exposure levels in a new Objective Spinal Motion Imaging Assessment system (OSMIA) based on low-dose fluoroscopy and image processing.

Methods: Fluoroscopic sequences in coronal and sagittal planes were obtained from 2 calibration models using dry lumbar vertebrae, plus the lumbar spines of 30 asymptomatic volunteers. Calibration model 1 (mobile) was screened upright, in 7 inter-vertebral positions. The volunteers and calibration model 2 (fixed) were screened on a motorized table comprising 2 horizontal sections, one of which moved through 80 degrees. Model 2 was screened during motion 5 times and the L2-S1 levels of the volunteers twice. Images were digitised at 5fps. Inter-vertebral motion from model 1 was compared to its pre-settings to investigate accuracy. For volunteers and model 2, the first digitised image in each sequence was marked with templates. Vertebrae were tracked throughout the motion using automated frame-to-frame registration. For each frame, vertebral angles were subtracted giving inter-vertebral motion graphs. Volunteer data were acquired twice on the same day and analysed by two blinded observers. The root-mean-square (RMS) differences between paired data were used as the measure of reliability.

Results: RMS difference between reference and computed inter-vertebral angles in model 1 was 0.32 degrees for side-bending and 0.52 degrees for flexion-extension. For model 2, X-ray positioning contributed more to the variance of range measurement than did automated registration. For volunteer image sequences, RMS inter-observer variation in intervertebral motion range in the coronal plane was 1.86 degrees and intra-subject biological variation was between 2.75 degrees and 2.91 degrees. RMS inter-observer variation in the sagittal plane was 1.94 degrees. Radiation dosages in each view were below the levels recommended for a plain film.

Conclusion: OSMIA can measure inter-vertebral angular motion patterns in routine clinical settings if modern image intensifier systems are used. It requires skillful radiography to achieve optimal positioning and dose limitation. Reliability in individual subjects can be judged from the variance of their averaged inter-vertebral angles and by observing automated image registration.

PubMed Disclaimer

Figures

Figure 1
Figure 1
The OSMIA image acquisition system.
Figure 2
Figure 2
Swing table and fluoroscope configuration. (Atlas Clinical Ltd)
Figure 3
Figure 3
First digital image in a side bending sequence, cursor-marked with external (tracking) and internal (visual) templates.
Figure 4
Figure 4
Calibration model 1. with inter-body universal joint and calibrated protractors for intervertebral angle and whole model rotational settings
Figure 5
Figure 5
Digitised fluoroscopic images of calibration model 2 right rotated (a), neutral (b) and left rotated (c).
Figure 6
Figure 6
Example of a graph that met the criteria for entry into pool of intervertebral motion graphs; 5 consecutive trackings (relative to the computer's X-axis) of a series of vertebral angles that coincide visually. (acquisition at 5 f/s for 8-bit images)
Figure 7
Figure 7
Example from intervertebral motion graph pool. Solid line is median of 25 differences between adjacent vertebral angle series' that met the criteria for inclusion. Scatter plot represents all data points. (acquisition at 5 f/s for 8-bit images).
Figure 8
Figure 8
Example of L4-5 intervertebral angle series of 120 frames in sidebending; 2 screenings 30 minutes apart, analysed by 2 blinded observers. (Convention: left sidebending is +ve in graphs).

References

    1. Todd TW, Pyle IS. A quantitative study of the vertebral column by direct roentgenologic methods. Amer J Phys Anthr. 1928;12:321. doi: 10.1002/ajpa.1330120211. - DOI
    1. Gianturco C. A roentgen analysis of the motion of the lower lumbar vertebrae in normal individuals and in patients with low back pain. Am J Roentgenol. 1944;52:261.
    1. Hasner E, Schalimtzek M, Snorrason E. Roentgenological examination of the function of the lumbar spine. Acta Radiol. 1952;37:141–149. - PubMed
    1. Knutsson F. The instability associated with disc generation in the lumbar spine. Acta Radiol. 1944;25:593–609.
    1. Morgan FP, King I. Primary instability of lumbar vertebrae as a common cause of low back pain. J Bone Joint Surg. 1957;39B:6–22. - PubMed

Publication types

LinkOut - more resources