A new approach for non-intrusive monitoring of blood pressure on a toilet seat
- PMID: 16400206
- DOI: 10.1088/0967-3334/27/2/010
A new approach for non-intrusive monitoring of blood pressure on a toilet seat
Abstract
Pulse arrival time (PAT) was measured non-intrusively to estimate each individual's blood pressure. Electrocardiogram (ECG) was measured with copper-coated electrodes and photoplethysmogram (PPG) was measured using a specially designed toilet seat apparatus. Non-intrusively measured PATs were compared with PATs measured by the standard method, and the results showed a good correlation. An equation was used to estimate blood pressure from the measured PAT during a training period for each individual. Estimated blood pressures were compared with measured blood pressures in a series of blood pressure varying experiments. For each individual, the estimated blood pressure was similar to the measured blood pressure within a tolerable error range. This method was also practiced for long-term monitoring, and the results show the value of this method for continuous home monitoring of blood pressure.
Similar articles
-
Enhancing the estimation of blood pressure using pulse arrival time and two confounding factors.Physiol Meas. 2010 Feb;31(2):145-57. doi: 10.1088/0967-3334/31/2/002. Epub 2009 Dec 11. Physiol Meas. 2010. PMID: 20009186
-
Development of a nonintrusive blood pressure estimation system for computer users.Telemed J E Health. 2007 Feb;13(1):57-64. doi: 10.1089/tmj.2006.0034. Telemed J E Health. 2007. PMID: 17309356
-
Effect of confounding factors on blood pressure estimation using pulse arrival time.Physiol Meas. 2008 May;29(5):615-24. doi: 10.1088/0967-3334/29/5/007. Epub 2008 May 7. Physiol Meas. 2008. PMID: 18460767
-
[Practical questions related to self-measurement of blood pressure].Ned Tijdschr Geneeskd. 2008 Mar 8;152(10):546-9. Ned Tijdschr Geneeskd. 2008. PMID: 18402319 Review. Dutch.
-
The value of self-measured home blood pressure in predicting stroke.Expert Rev Neurother. 2006 Feb;6(2):163-73. doi: 10.1586/14737175.6.2.163. Expert Rev Neurother. 2006. PMID: 16466296 Review.
Cited by
-
Calibration-Free Cuffless Blood Pressure Estimation Based on a Population With a Diverse Range of Age and Blood Pressure.Front Med Technol. 2021 Jul 27;3:695356. doi: 10.3389/fmedt.2021.695356. eCollection 2021. Front Med Technol. 2021. PMID: 35047937 Free PMC article.
-
Nontraditional Electrocardiogram and Algorithms for Inconspicuous In-Home Monitoring: Comparative Study.JMIR Mhealth Uhealth. 2018 May 28;6(5):e120. doi: 10.2196/mhealth.9604. JMIR Mhealth Uhealth. 2018. PMID: 29807881 Free PMC article.
-
Flexible capacitive electrodes for minimizing motion artifacts in ambulatory electrocardiograms.Sensors (Basel). 2014 Aug 12;14(8):14732-43. doi: 10.3390/s140814732. Sensors (Basel). 2014. PMID: 25120162 Free PMC article.
-
Binodal, wireless epidermal electronic systems with in-sensor analytics for neonatal intensive care.Science. 2019 Mar 1;363(6430):eaau0780. doi: 10.1126/science.aau0780. Science. 2019. PMID: 30819934 Free PMC article.
-
Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice.IEEE Trans Biomed Eng. 2015 Aug;62(8):1879-901. doi: 10.1109/TBME.2015.2441951. Epub 2015 Jun 5. IEEE Trans Biomed Eng. 2015. PMID: 26057530 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources