The value of onsite adequacy assessment of thyroid fine-needle aspirations is a function of operator experience
Abstract
Background: Cytotechnologists and pathologists often perform onsite evaluations of thyroid fine-needle aspirations (FNAs) to provide immediate feedback regarding whether adequate material has been obtained for cytologic diagnosis. The current study was designed to determine whether onsite adequacy assessment results in a significant decrease in nondiagnostic specimens between ultrasound (US)-guided FNAs of the thyroid and those performed by palpation alone.
Methods: A search was performed to identify in-house thyroid FNAs performed between January 1, 2000 and December 31, 2003 that were obtained under US guidance or by palpation only. It was then recorded whether an onsite adequacy assessment was performed. The submitting physician and final diagnosis also were recorded for each case. Contingency tables were constructed and evaluated using chi-square analysis.
Results: Of 1502 in-house thyroid FNAs included in the current study, 981 (65.3%) were performed under US guidance and 521 (34.7%) were performed with palpation alone. Onsite adequacy assessment of the aspirated material was performed in 323 cases (21.5%), whereas 1179 cases (78.5%) were performed without onsite evaluation. Of the 418 palpation-guided FNAs that were performed without adequacy assessment, 70 (16.7%) were reported to be nondiagnostic, whereas of the 103 palpation-guided FNAs with immediate evaluation, only 7 (6.8%) were determined to be inadequate for diagnosis. This difference was statistically significant (P < 0.025). Of 761 US-guided FNAs without immediate adequacy assessment, 54 (7.1%) were nondiagnostic, which was not statistically different from the nondiagnostic rate of 4.5% (10 of 220 cases) for US-guided FNAs with onsite evaluation. However, when these US-guided FNAs were divided further into 2 groups based on the experience of the radiologist performing the FNA, the nondiagnostic rate in the group of experienced radiologists was only 5.4% (or 32 of 592 US-guided FNAs), even though onsite evaluation was not performed. Among radiologists with less experience, adequacy assessment significantly reduced the nondiagnostic rate from 13.0% (22 of 169 FNAs without adequacy assessment) to 4.5% (10 of 220 FNAs with adequacy assessment) (P < 0.01).
Conclusions: The results of the current study demonstrate that onsite adequacy assessment of thyroid FNAs significantly reduces the number of nondiagnostic aspirates. However, the benefit of onsite evaluation, at least for US-guided FNAs, depends on the experience of the radiologist. In the current study, experienced radiologists with a relatively low nondiagnostic rate did not benefit from onsite adequacy assessment. This finding confirms the importance of experience in the performance of FNA, but suggests that onsite adequacy assessment may assist the less experienced operator.
Copyright 2006 American Cancer Society.
Similar articles
-
Cost-effectiveness of immediate specimen adequacy assessment of thyroid fine-needle aspirations.Am J Clin Pathol. 2004 Jan;121(1):64-9. doi: 10.1309/XLND-TE28-9WAQ-YK0Y. Am J Clin Pathol. 2004. PMID: 14750242
-
Specimen adequacy and diagnostic specificity of ultrasound-guided fine needle aspirations of nonpalpable thyroid nodules.Diagn Cytopathol. 2006 Mar;34(3):188-90. doi: 10.1002/dc.20392. Diagn Cytopathol. 2006. PMID: 16470862
-
How important is on-site adequacy assessment for thyroid FNA? An evaluation of 883 cases.Diagn Cytopathol. 2007 Mar;35(3):183-6. doi: 10.1002/dc.20552. Diagn Cytopathol. 2007. PMID: 17304536
-
Timing of repeat thyroid fine-needle aspiration in the management of thyroid nodules.Acta Cytol. 2011;55(6):544-8. doi: 10.1159/000334214. Epub 2011 Dec 9. Acta Cytol. 2011. PMID: 22156464 Review.
-
Assessing Adequacy: A Meta-Analysis of Rapid Onsite Evaluation of Thyroid Nodules.J Surg Res. 2024 Apr;296:523-531. doi: 10.1016/j.jss.2024.01.018. Epub 2024 Feb 7. J Surg Res. 2024. PMID: 38330678 Review.
Cited by
-
Effects of Rapid On-Site Evaluation on Diagnostic Accuracy of Thyroid Fine-Needle Aspiration.Acta Cytol. 2022;66(5):371-378. doi: 10.1159/000522662. Epub 2022 May 5. Acta Cytol. 2022. PMID: 35512664 Free PMC article.
-
Ultrasound-Guided Fine-Needle Biopsy of First 1000 Consecutive Thyroid Nodules: Single-Surgeon Experience.OTO Open. 2020 Jun 2;4(2):2473974X20929008. doi: 10.1177/2473974X20929008. eCollection 2020 Apr-Jun. OTO Open. 2020. PMID: 32537553 Free PMC article.
-
This 'Rose' Has no Thorns-Diagnostic Utility of 'Rapid On-Site Evaluation' (ROSE) in Fine Needle Aspiration Cytology.Indian J Surg Oncol. 2019 Dec;10(4):688-698. doi: 10.1007/s13193-019-00981-y. Epub 2019 Sep 12. Indian J Surg Oncol. 2019. PMID: 31857767 Free PMC article.
-
Role of operator experience in ultrasound-guided fine-needle aspiration biopsy of the thyroid.Radiol Med. 2010 Jun;115(4):612-8. doi: 10.1007/s11547-010-0528-x. Epub 2010 Feb 22. Radiol Med. 2010. PMID: 20177981 English, Italian.
-
Value of rapid on-site evaluation for ultrasound-guided thyroid fine needle aspiration.J Int Med Res. 2019 Feb;47(2):626-634. doi: 10.1177/0300060518807060. Epub 2018 Nov 21. J Int Med Res. 2019. PMID: 30463462 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical