Impact of prosthesis-patient mismatch on cardiac events and midterm mortality after aortic valve replacement in patients with pure aortic stenosis
- PMID: 16401767
- DOI: 10.1161/CIRCULATIONAHA.105.587022
Impact of prosthesis-patient mismatch on cardiac events and midterm mortality after aortic valve replacement in patients with pure aortic stenosis
Erratum in
- Circulation. 2006 Feb 21;113(7):e288. Quiani, Eugenio [corrected to Quaini, Eugenio]
Abstract
Background: Prosthesis-patient mismatch (PPM) occurs when the effective orifice area (EOA) of the prosthesis being implanted is too small in relation to body size, thus causing abnormally high transvalvular pressure gradients. The objective of this study was to examine the midterm impact of PPM on overall mortality and cardiac events after aortic valve replacement in patients with pure aortic stenosis.
Methods and results: The indexed EOA (EOAi) was estimated for each type and size of prosthesis being implanted in 315 consecutive patients with pure aortic stenosis. PPM was defined as an EOAi < or =0.80 cm2/m2 and was correlated with overall mortality and cardiac events. PPM was present in 47% of patients. The 5-year overall survival and cardiac event-free survival were 82+/-3% and 75+/-4%, respectively, in patients with PPM compared with 93+/-3% and 87+/-4% in patients with no PPM (P< or =0.01). In multivariate analysis, PPM was associated with a 4.2-fold (95% CI, 1.6 to 11.3) increase in the risk of overall mortality and 3.2-fold (95% CI, 1.5 to 6.8) increase in the risk of cardiac events. The other independent risk factors were history of heart failure, NHYA class III-IV, severe left ventricular hypertrophy, and absence of normal sinus rhythm before operation.
Conclusions: PPM is an independent predictor of cardiac events and midterm mortality in patients with pure aortic stenosis undergoing aortic valve replacement. As opposed to other risk factors, PPM may be avoided or its severity may be reduced with the use of a preventive strategy at the time of operation.
Similar articles
-
Effect of the prosthesis-patient mismatch on long-term clinical outcomes after isolated aortic valve replacement for aortic stenosis: a prospective observational study.J Thorac Cardiovasc Surg. 2013 Nov;146(5):1098-104. doi: 10.1016/j.jtcvs.2012.07.101. Epub 2012 Sep 7. J Thorac Cardiovasc Surg. 2013. PMID: 22959323
-
Aortic valve prosthesis-patient mismatch and long-term outcomes: 19-year single-center experience.Ann Thorac Surg. 2013 Sep;96(3):844-50. doi: 10.1016/j.athoracsur.2013.04.075. Epub 2013 Jun 25. Ann Thorac Surg. 2013. PMID: 23810177
-
Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement.Circulation. 2003 Aug 26;108(8):983-8. doi: 10.1161/01.CIR.0000085167.67105.32. Epub 2003 Aug 11. Circulation. 2003. PMID: 12912812
-
Impact of the indexed effective orifice area on mid-term cardiac-related mortality after aortic valve replacement.Heart. 2010 Jun;96(11):865-71. doi: 10.1136/hrt.2009.177220. Epub 2010 Apr 20. Heart. 2010. PMID: 20406767 Review.
-
Indexed effective orifice area is a significant predictor of higher mid- and long-term mortality rates following aortic valve replacement in patients with prosthesis-patient mismatch.Eur J Cardiothorac Surg. 2014 Feb;45(2):234-40. doi: 10.1093/ejcts/ezt245. Epub 2013 May 16. Eur J Cardiothorac Surg. 2014. PMID: 23682010 Review.
Cited by
-
Impact of patient-prosthesis mismatch on 30-day outcomes in young and middle-aged patients undergoing aortic valve replacement.J Cardiothorac Surg. 2012 May 15;7:46. doi: 10.1186/1749-8090-7-46. J Cardiothorac Surg. 2012. PMID: 22587627 Free PMC article.
-
Prevention of valve prosthesis--patient mismatch before aortic valve replacement: does it matter and is it feasible?Heart. 2007 May;93(5):549-51. doi: 10.1136/hrt.2006.107672. Heart. 2007. PMID: 17435068 Free PMC article.
-
Impact of energy loss index on left ventricular mass regression after aortic valve replacement.J Echocardiogr. 2014;12(2):51-8. doi: 10.1007/s12574-013-0196-7. Epub 2013 Nov 26. J Echocardiogr. 2014. PMID: 24955015 Free PMC article.
-
Obesity and the risk of late mortality after aortic valve replacement with small prosthesis.J Cardiothorac Surg. 2013 Jul 15;8:174. doi: 10.1186/1749-8090-8-174. J Cardiothorac Surg. 2013. PMID: 23856275 Free PMC article.
-
Incidence and Impact of Patient-Prosthesis Mismatch in Isolated Aortic Valve Surgery.Open Access Maced J Med Sci. 2015 Dec 15;3(4):624-9. doi: 10.3889/oamjms.2015.108. Epub 2015 Oct 15. Open Access Maced J Med Sci. 2015. PMID: 27275298 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Research Materials