Abstract
Background: New ablation strategies for atrial fibrillation or nonidiopathic ventricular tachycardia are increasingly based on anatomic consideration and require the placement of ablation lesions at the correct anatomic locations. This study sought to evaluate the accuracy of the first clinically available image integration system for catheter ablation on 3-dimensional (3D) computed tomography (CT) images in real time.
Methods and results: After midline sternotomy, 2.3-mm CT fiducial markers were attached to the epicardial surface of each cardiac chamber in 9 mongrel dogs. Detailed 3D cardiac anatomy was reconstructed from contrast-enhanced, high-resolution CT images and registered to the electroanatomic maps of each cardiac chamber. To assess accuracy, targeted ablations were performed at each of the fiducial markers guided only by the reconstructed 3D images. At autopsy, the position error was 1.9+/-0.9 mm for the right atrium, 2.7+/-1.2 mm for the right ventricle, 1.8+/-1.0 mm for the left atrium, and 2.3+/-1.1 mm for the left ventricle. To evaluate the system's guidance of more complex clinical ablation strategies, ablations of the cavotricuspid isthmus (n=4), fossa ovalis (n=4), and pulmonary veins (n=6) were performed, which resulted in position errors of 1.8+/-1.5, 2.2+/-1.3, and 2.1+/-1.2 mm, respectively. Retrospective analysis revealed that a combination of landmark registration and the target chamber surface registration resulted in <3 mm accuracy in all 4 cardiac chambers.
Conclusions: Image integration with high-resolution 3D CT allows accurate placement of anatomically guided ablation lesions and can facilitate complex ablation strategies. This may provide significant advantages for anatomically based procedures such as ablation of atrial fibrillation and nonidiopathic ventricular tachycardia.
Similar articles
-
Initial experience in the use of integrated electroanatomic mapping with three-dimensional MR/CT images to guide catheter ablation of atrial fibrillation.J Cardiovasc Electrophysiol. 2006 May;17(5):459-66. doi: 10.1111/j.1540-8167.2006.00425.x. J Cardiovasc Electrophysiol. 2006. PMID: 16684014 Clinical Trial.
-
Anatomic stereotactic catheter ablation on three-dimensional magnetic resonance images in real time.Circulation. 2003 Nov 11;108(19):2407-13. doi: 10.1161/01.CIR.0000093191.05433.B0. Epub 2003 Oct 20. Circulation. 2003. PMID: 14568905
-
Registration of three-dimensional left atrial computed tomographic images with projection images obtained using fluoroscopy.Circulation. 2005 Dec 13;112(24):3763-8. doi: 10.1161/CIRCULATIONAHA.105.565218. Circulation. 2005. PMID: 16344405
-
Imaging techniques in cardiac electrophysiology.Expert Rev Cardiovasc Ther. 2006 Jan;4(1):59-70. doi: 10.1586/14779072.4.1.59. Expert Rev Cardiovasc Ther. 2006. PMID: 16375629 Review.
-
Integration of cardiac imaging and electrophysiology during catheter ablation procedures for atrial fibrillation.J Electrocardiol. 2006 Oct;39(4 Suppl):S188-92. doi: 10.1016/j.jelectrocard.2006.05.032. Epub 2006 Sep 6. J Electrocardiol. 2006. PMID: 16950332 Review.
Cited by
-
Registration of 3D computed tomographic images with interventional systems: implications for catheter ablation of atrial fibrillation.J Interv Card Electrophysiol. 2006 Sep;16(3):141-8. doi: 10.1007/s10840-006-9030-8. Epub 2006 Dec 1. J Interv Card Electrophysiol. 2006. PMID: 17139556 Review.
-
Multimodal data integration for computer-aided ablation of atrial fibrillation.J Biomed Biotechnol. 2008;2008:681303. doi: 10.1155/2008/681303. J Biomed Biotechnol. 2008. PMID: 18309371 Free PMC article.
-
CathROB: A Highly Compact and Versatile Remote Catheter Navigation System.Appl Bionics Biomech. 2017;2017:2712453. doi: 10.1155/2017/2712453. Epub 2017 May 25. Appl Bionics Biomech. 2017. PMID: 28630564 Free PMC article.
-
Left Atrial Appendage Volume and Plasma Docosahexaenoic Acid Levels Are Associated With Atrial Fibrillation Recurrence After Catheter Ablation.Cardiol Res. 2017 Jun;8(3):96-104. doi: 10.14740/cr542w. Epub 2017 Jun 30. Cardiol Res. 2017. PMID: 28725325 Free PMC article.
-
Cardiovascular Computed Tomography and Magnetic Resonance Imaging Guideline of the Brazilian Society of Cardiology and the Brazilian College of Radiology - 2024.Arq Bras Cardiol. 2024 Oct 28;121(9):e20240608. doi: 10.36660/abc.20240608. Arq Bras Cardiol. 2024. PMID: 39475988 Free PMC article. English, Portuguese. No abstract available.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical