Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1992 Jun;99(6):985-1016.
doi: 10.1085/jgp.99.6.985.

Separation of Q beta and Q gamma charge components in frog cut twitch fibers with tetracaine. Critical comparison with other methods

Affiliations
Comparative Study

Separation of Q beta and Q gamma charge components in frog cut twitch fibers with tetracaine. Critical comparison with other methods

C S Hui et al. J Gen Physiol. 1992 Jun.

Abstract

Charge movement was measured in frog cut twitch fibers with the double Vaseline-gap technique. 25 microM tetracaine had very little effect on the maximum amounts of Q beta and Q gamma but slowed the kinetics of the I gamma humps in the ON segments of TEST-minus-CONTROL current traces, giving rise to biphasic transients in the difference traces. This concentration of tetracaine also shifted V gamma 3.7 (SEM 0.7) mV in the depolarizing direction, resulting in a difference Q-V plot that was bell-shaped with a peak at approximately -50 mV. 0.5-1.0 mM tetracaine suppressed the total amount of charge. The suppressed component had a sigmoidal voltage distribution with V = -56.6 (SEM 1.1) mV, k = 2.5 (SEM 0.5) mV, and qmax/cm = 9.2 (SEM 1.5) nC/microF, suggesting that the tetracaine-sensitive charge had a steep voltage dependence, a characteristic of the Q gamma component. An intermediate concentration (0.1-0.5 mM) of tetracaine shifted V gamma and partially suppressed the tetracaine-sensitive charge, resulting in a difference Q-V plot that rose to a peak and then decayed to a plateau level. Following a TEST pulse to greater than -60 mV, the slow inward current component during a post-pulse to approximately -60 mV was also tetracaine sensitive. The voltage distribution of the charge separated by tetracaine (method 1) was compared with those separated by three other existing methods: (a) the charge associated with the hump component separated by a sum of two kinetic functions from the ON segment of a TEST-minus-CONTROL current trace (method 2), (b) the steeply voltage-dependent component separated from a Q-V plot of the total charge by fitting with a sum of two Boltzmann distribution functions (method 3), and (c) the sigmoidal component separated from the Q-V plot of the final OFF charge obtained with a two-pulse protocol (method 4). The steeply voltage-dependent components separated by all four methods are consistent with each other, and are therefore concluded to be equivalent to the same Q gamma component. The shortcomings of each separation method are critically discussed. Since each method has its own advantages and disadvantages, it is recommended that, as much as possible, Q gamma should be separated by more than one method to obtain more reliable results.

PubMed Disclaimer

Similar articles

Cited by

References

    1. J Physiol. 1991 Dec;444:579-603 - PubMed
    1. J Physiol. 1983 Apr;337:509-29 - PubMed
    1. J Gen Physiol. 1991 Aug;98(2):315-47 - PubMed
    1. J Gen Physiol. 1991 Sep;98(3):429-64 - PubMed
    1. J Gen Physiol. 1991 Aug;98(2):287-314 - PubMed

Publication types