Reproducibility of technetium-99m mercaptoacetyltriglycine clearance in patients with impaired renal function
- PMID: 16404234
- DOI: 10.1097/01.mnm.0000195674.75664.ba
Reproducibility of technetium-99m mercaptoacetyltriglycine clearance in patients with impaired renal function
Abstract
Background: The aim of this study was to determine the reproducibility of technetium-99m mercaptoacetyltriglycine (99mTc-MAG3) clearance in patients with a 99mTc-MAG3 clearance below 100 ml/min/1.73 m2.
Methods: Two separate multi-sample clearance studies were performed in 16 patients at a 1 week interval. The clearances were calculated according to the open two-compartment model of Sapirstein et al., accepting the 90, 120 and 180 min samples as the last points of the biexponential curve. The clearance measurements were also performed according to the single-sample methods of Russell et al. and Bubeck using the fitted value at 44 min.
Results: There was no significant difference between the two clearance measurements for all five samples (P>0.05). There was a systematic increase in clearance measurements of 8.0+/-2.7% from the 180 to 120 min samples and 4.8+/-2.0% from the 120 to 90 min samples. Both single-sample methods (Bubeck and Russell et al.) gave more divergent results than multi-sample methods. The mean and standard deviation (%) of the normalized differences between two successive tests were -3.9+/-12.6, -2.4+/-13.1, -1.9+/-14.9, -4.1+/-53.5 and -13+/-82.1 for 90, 120 and 180 min samples and the Russell et al. and Bubeck methods, respectively.
Conclusion: Single-sample methods give very poor reproducibility and accuracy and should not be used in patients with poor renal function. The reproducibility of 99mTc-MAG3 clearance using the multi-sample method (90 min) in patients with impaired renal function is 12.6%, which is similar to that in patients with good renal function and that obtained with other tubular agents. Whether this level of reproducibility is satisfactory for documenting serial changes in an individual patient with a 99mTc-MAG3 clearance below 100 ml/min/1.73 m2 depends on the expectation of the clinician.
Similar articles
-
A comparison of single plasma sample methods to estimate renal clearance using 99mTc-ethylenedicysteine and 99mTc-mercaptoacetyltriglycine.Clin Physiol Funct Imaging. 2013 Sep;33(5):353-8. doi: 10.1111/cpf.12034. Epub 2013 Mar 18. Clin Physiol Funct Imaging. 2013. PMID: 23701132
-
Estimation of 99mTc-MAG3 clearance by single-sample methods and camera-based methods.Ann Nucl Med. 2000 Oct;14(5):329-32. doi: 10.1007/BF02988691. Ann Nucl Med. 2000. PMID: 11108160
-
Reproducibility of technetium-99m-MAG3 clearance using the Bubeck method.J Nucl Med. 1998 Jun;39(6):1066-9. J Nucl Med. 1998. PMID: 9627345
-
99mTc-MAG3: review of pharmacokinetics, clinical application to renal diseases and quantification of renal function.Ann Nucl Med. 2001 Jun;15(3):179-90. doi: 10.1007/BF02987829. Ann Nucl Med. 2001. PMID: 11545186 Review.
-
Computer-assisted diagnosis in renal nuclear medicine: rationale, methodology, and interpretative criteria for diuretic renography.Semin Nucl Med. 2014 Mar;44(2):146-58. doi: 10.1053/j.semnuclmed.2013.10.007. Semin Nucl Med. 2014. PMID: 24484751 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical