A SU-8/PDMS hybrid microfluidic device with integrated optical fibers for online monitoring of lactate
- PMID: 16404510
- DOI: 10.1007/s10544-005-6074-y
A SU-8/PDMS hybrid microfluidic device with integrated optical fibers for online monitoring of lactate
Abstract
A microfluidic device with integrated optical fibres was developed for online monitoring of lactate. The device consists of a SU-8 waveguide, microfluidic channels and grooves for the insertion of optic fibres. It was fabricated by one-step photolithography of SU-8 polymer resist. Different channel widths (50-300 microm) were tested in terms of detection sensitivity. A wide range of flow rates were applied to investigate the influence of flow rate on signal fluctuations. The separation between optical fibre sensor and microfluidic channel and the width of fluidic channel have been optimized to maximize the detection sensitivity. It was revealed that 250 microm of channel width is the optimum light path length for a compromise between detection sensitivity and interference of ambient light. The independence of detection signals on flow rates was demonstrated within the range of flow rate (0.5-5 ml/hr) tested. Compared with conventional lactate detection, the device is proved to have high accuracy, relatively low limit of detection (50 mg/L) and reasonably fast response time (100 sec). The fabrication of device is simple and low cost. The present work has provided some fundamental data for further system optimization to meet specific detection requirements.
Similar articles
-
Study of on-line monitoring of lactate based on optical fibre sensor and in-channel mixing mechanism.Biomed Microdevices. 2007 Apr;9(2):167-74. doi: 10.1007/s10544-006-9018-2. Biomed Microdevices. 2007. PMID: 17160706
-
Flow-through functionalized PDMS microfluidic channels with dextran derivative for ELISAs.Lab Chip. 2009 May 7;9(9):1243-7. doi: 10.1039/b816018j. Epub 2009 Jan 20. Lab Chip. 2009. PMID: 19370243
-
Miniaturized one-chip electrochemical sensing device integrated with a dialysis membrane and double thin-layer flow channels for measuring blood samples.Biosens Bioelectron. 2006 Feb 15;21(8):1649-53. doi: 10.1016/j.bios.2005.07.016. Epub 2005 Aug 29. Biosens Bioelectron. 2006. PMID: 16129595
-
Microfluidic immunosensor systems.Biosens Bioelectron. 2005 Jun 15;20(12):2488-503. doi: 10.1016/j.bios.2004.10.016. Epub 2004 Dec 8. Biosens Bioelectron. 2005. PMID: 15854821 Review.
-
Macro-to-micro interfaces for microfluidic devices.Lab Chip. 2004 Dec;4(6):526-33. doi: 10.1039/b410720a. Epub 2004 Nov 10. Lab Chip. 2004. PMID: 15570361 Review.
Cited by
-
Contact printing of arrayed microstructures.Anal Bioanal Chem. 2010 Aug;397(8):3377-85. doi: 10.1007/s00216-010-3728-2. Epub 2010 Apr 28. Anal Bioanal Chem. 2010. PMID: 20425106 Free PMC article.
-
Interplay between materials and microfluidics.Nat Rev Mater. 2017 May;2(5):17016. doi: 10.1038/natrevmats.2017.16. Epub 2017 Apr 20. Nat Rev Mater. 2017. PMID: 38993477 Free PMC article.
-
Design and microfabrication of a miniature fiber optic probe with integrated lenses and mirrors for Raman and fluorescence measurements.Anal Bioanal Chem. 2017 Jan;409(1):275-285. doi: 10.1007/s00216-016-9999-5. Epub 2016 Oct 20. Anal Bioanal Chem. 2017. PMID: 27766359 Free PMC article.
-
Sealing SU-8 microfluidic channels using PDMS.Biomicrofluidics. 2011 Dec;5(4):46503-465038. doi: 10.1063/1.3659016. Epub 2011 Nov 9. Biomicrofluidics. 2011. PMID: 22662066 Free PMC article.
-
Fully inkjet-printed microfluidics: a solution to low-cost rapid three-dimensional microfluidics fabrication with numerous electrical and sensing applications.Sci Rep. 2016 Oct 7;6:35111. doi: 10.1038/srep35111. Sci Rep. 2016. PMID: 27713545 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources