Mechanical and optical anisotropy of bovine pericardium
- PMID: 1640759
- DOI: 10.1007/BF02446197
Mechanical and optical anisotropy of bovine pericardium
Abstract
A Moiré fringe method was used to determine the shape of inflated disks of fresh bovine pericardium. The results suggested that the tissue was anisotropic and allowed the identification of the directions of the axes of elastic symmetry. Quantitative biaxial inflation and simple tension tests confirmed the anisotropy. In the circumferential direction the tissue was more extensible and had greater mean strength (18 MPa against 2.5 MPa) and mean terminal modulus (46 MPa against 14 MPa) than in the root-to-apex direction. The tissue was also optically anisotropic when viewed by transmitted polarised light and the directions of mechanical and optical anisotropy were related.
Similar articles
-
Biaxial mechanical/structural effects of equibiaxial strain during crosslinking of bovine pericardial xenograft materials.Biomaterials. 1999 Jan;20(2):137-53. doi: 10.1016/s0142-9612(98)00142-2. Biomaterials. 1999. PMID: 10022783
-
Anisotropic elasticity and strength of glutaraldehyde fixed bovine pericardium for use in pericardial bioprosthetic valves.J Biomed Mater Res. 1994 Jan;28(1):49-57. doi: 10.1002/jbm.820280107. J Biomed Mater Res. 1994. PMID: 8126028
-
Pre-use intraoperative testing of autologous tissue for valvular surgery: a proof of concept study.J Heart Valve Dis. 1999 Nov;8(6):614-23; discussion 623-4. J Heart Valve Dis. 1999. PMID: 10616237
-
Donkey pericardium as an alternative bioprosthetic heart valve material.Artif Organs. 2013 Mar;37(3):248-55. doi: 10.1111/j.1525-1594.2012.01549.x. Epub 2012 Nov 12. Artif Organs. 2013. PMID: 23145868
-
Mechanical testing of pericardium for manufacturing prosthetic heart valves.Interact Cardiovasc Thorac Surg. 2016 Jan;22(1):72-84. doi: 10.1093/icvts/ivv282. Epub 2015 Oct 21. Interact Cardiovasc Thorac Surg. 2016. PMID: 26489665 Review.
Cited by
-
Biomechanics of the fetal membrane prior to mechanical failure: review and implications.Eur J Obstet Gynecol Reprod Biol. 2009 May;144 Suppl 1(Suppl 1):S121-7. doi: 10.1016/j.ejogrb.2009.02.014. Epub 2009 Mar 19. Eur J Obstet Gynecol Reprod Biol. 2009. PMID: 19303191 Free PMC article. Review.
-
Mechanical considerations for polymeric heart valve development: Biomechanics, materials, design and manufacturing.Biomaterials. 2019 Dec;225:119493. doi: 10.1016/j.biomaterials.2019.119493. Epub 2019 Sep 17. Biomaterials. 2019. PMID: 31569017 Free PMC article. Review.
-
Hysteresis of a biomaterial: influence of sutures and biological adhesives.J Mater Sci Mater Med. 2007 May;18(5):715-24. doi: 10.1007/s10856-006-0009-x. Epub 2006 Nov 30. J Mater Sci Mater Med. 2007. PMID: 17136602
-