Performance of a linear ion trap-Orbitrap hybrid for peptide analysis
- PMID: 16408932
- DOI: 10.1021/ac0514624
Performance of a linear ion trap-Orbitrap hybrid for peptide analysis
Abstract
Proteomic analysis of digested complex protein mixtures has become a useful strategy to identify proteins involved in biological processes. We have evaluated the use of a new mass spectrometer that combines a linear ion trap and an Orbitrap to create a hybrid tandem mass spectrometer. A digested submandibular/sublingual saliva sample was used for the analysis. We find the instrument is capable of mass resolution in excess of 40,000 and mass measurement accuracies of less than 2 ppm for the analysis of complex peptide mixtures. Such high mass accuracy allowed the elimination of virtually any false positive peptide identifications, suggesting that peptides that do not match the specificity of the protease used in the digestion of the sample should not automatically be considered as false positives. Tandem mass spectra from the linear ion trap and from the Orbitrap have very similar ion abundance ratios. We conclude this instrument will be well suited for shotgun proteomic types of analyses.
Similar articles
-
The benefit of combining nLC-MALDI-Orbitrap MS data with nLC-MALDI-TOF/TOF data for proteomic analyses employing elastase.J Proteome Res. 2009 Nov;8(11):5317-24. doi: 10.1021/pr900557k. J Proteome Res. 2009. PMID: 19725589
-
Higher-energy C-trap dissociation for peptide modification analysis.Nat Methods. 2007 Sep;4(9):709-12. doi: 10.1038/nmeth1060. Epub 2007 Aug 26. Nat Methods. 2007. PMID: 17721543
-
Analysis of peptide MS/MS spectra from large-scale proteomics experiments using spectrum libraries.Anal Chem. 2006 Aug 15;78(16):5678-84. doi: 10.1021/ac060279n. Anal Chem. 2006. PMID: 16906711
-
Utility of mass spectrometry for proteome analysis: part I. Conceptual and experimental approaches.Expert Rev Proteomics. 2008 Dec;5(6):841-64. doi: 10.1586/14789450.5.6.841. Expert Rev Proteomics. 2008. PMID: 19086863 Review.
-
Orbitrap mass spectrometry: instrumentation, ion motion and applications.Mass Spectrom Rev. 2008 Nov-Dec;27(6):661-99. doi: 10.1002/mas.20186. Mass Spectrom Rev. 2008. PMID: 18683895 Review.
Cited by
-
A proteomics grade electron transfer dissociation-enabled hybrid linear ion trap-orbitrap mass spectrometer.J Proteome Res. 2008 Aug;7(8):3127-36. doi: 10.1021/pr800264t. Epub 2008 Jul 10. J Proteome Res. 2008. PMID: 18613715 Free PMC article.
-
Analysis of tandem mass spectra by FTMS for improved large-scale proteomics with superior protein quantification.Anal Chem. 2010 Jan 1;82(1):316-22. doi: 10.1021/ac902005s. Anal Chem. 2010. PMID: 19938823 Free PMC article.
-
Mass Spectrometric Analysis of Cerebrospinal Fluid Ubiquitin in Alzheimer's Disease and Parkinsonian Disorders.Proteomics Clin Appl. 2017 Dec;11(11-12):1700100. doi: 10.1002/prca.201700100. Epub 2017 Nov 2. Proteomics Clin Appl. 2017. PMID: 28972305 Free PMC article.
-