Simulating the response of terahertz radiation to basal cell carcinoma using ex vivo spectroscopy measurements
- PMID: 16409086
- DOI: 10.1117/1.2137667
Simulating the response of terahertz radiation to basal cell carcinoma using ex vivo spectroscopy measurements
Abstract
Studies of basal cell carcinoma using terahertz pulsed imaging have revealed a significant difference between regions of tumor and healthy tissue. These differences are manifested in the reflected pulse due to what is thought to be changes in refractive index and absorption. We present measurements of the refractive index and absorption coefficient of excised normal tissue and basal cell carcinoma using terahertz (THz) transmission spectroscopy. We extract Debye parameters from these data and enter them into a finite difference time domain simulation to predict the shape of the waveforms reflected off the normal tissue and basal cell carcinoma and compare them with published in vivo data. Simulating the interaction of terahertz radiation with normal and cancerous tissue is a key step toward understanding the origin of contrast in terahertz images of skin cancer.
Similar articles
-
Terahertz pulsed spectroscopy of human Basal cell carcinoma.Appl Spectrosc. 2006 Oct;60(10):1127-33. doi: 10.1366/000370206778664635. Appl Spectrosc. 2006. PMID: 17059664
-
Terahertz pulse imaging in reflection geometry of human skin cancer and skin tissue.Phys Med Biol. 2002 Nov 7;47(21):3853-63. doi: 10.1088/0031-9155/47/21/325. Phys Med Biol. 2002. PMID: 12452577 Review.
-
Terahertz pulse imaging of ex vivo basal cell carcinoma.J Invest Dermatol. 2003 Jan;120(1):72-8. doi: 10.1046/j.1523-1747.2003.12013.x. J Invest Dermatol. 2003. PMID: 12535200
-
Elastic scattering spectroscopy in assessing skin lesions: an "in vivo" study.Photodiagnosis Photodyn Ther. 2012 Jun;9(2):132-41. doi: 10.1016/j.pdpdt.2011.12.003. Epub 2011 Dec 27. Photodiagnosis Photodyn Ther. 2012. PMID: 22594983
-
Etiology and pathogenesis of basal cell carcinoma.Clin Dermatol. 1995 Nov-Dec;13(6):527-36. doi: 10.1016/0738-081x(95)00062-k. Clin Dermatol. 1995. PMID: 8882763 Review. No abstract available.
Cited by
-
Cole-Cole Model for the Dielectric Characterization of Healthy Skin and Basal Cell Carcinoma at THz Frequencies.IEEE Open J Eng Med Biol. 2024 Aug 5;5:600-606. doi: 10.1109/OJEMB.2024.3438562. eCollection 2024. IEEE Open J Eng Med Biol. 2024. PMID: 39184967 Free PMC article.
-
Millimeter-wave emissivity as a metric for the non-contact diagnosis of human skin conditions.Bioelectromagnetics. 2017 Oct;38(7):559-569. doi: 10.1002/bem.22074. Epub 2017 Aug 24. Bioelectromagnetics. 2017. PMID: 28836682 Free PMC article.
-
The potential of terahertz sensing for cancer diagnosis.Heliyon. 2020 Dec 3;6(12):e05623. doi: 10.1016/j.heliyon.2020.e05623. eCollection 2020 Dec. Heliyon. 2020. PMID: 33305055 Free PMC article.
-
Terahertz spectroscopic imaging and properties of gastrointestinal tract in a rat model.Biomed Opt Express. 2014 Nov 5;5(12):4162-70. doi: 10.1364/BOE.5.004162. eCollection 2014 Dec 1. Biomed Opt Express. 2014. PMID: 25574429 Free PMC article.
-