Scipione Riva-Rocci and the men behind the mercury sphygmomanometer
- PMID: 16409431
- DOI: 10.1111/j.1742-1241.2005.00548.x
Scipione Riva-Rocci and the men behind the mercury sphygmomanometer
Abstract
The history of the blood pressure (BP) concept and measurements is described. Many scientists were involved. Among them, major triumphs were achieved by William Harvey during the early 1600s who announced that there is a finite amount of blood that circulated the body in one direction only. In the mid-1700s, Reverend Stephen Hales reported the first invasive measurement in horses and smaller animals. Poiseuille introduced in the early 1800s the mercury hydrodynometer and the mmHg units. Karl von-Vierordt described in 1855 that with enough pressure, the arterial pulse could be obliterated. He also created the sphygmograph, a pulse recorder usable for routine non-invasive monitoring on humans. In 1881, von Basch created the sphygmomanometer and the first non-invasive BP measurements. However, in 1896, Scipione Riva-Rocci developed further the mercury sphygmomanometer, almost as we know it today. The sphygmomanometer could only be used to determine the systolic BP. Observing the pulse disappearance via palpitation would only allow the measuring physician to observe the point when the artery was fully constricted. Nikolai Korotkoff was the first to observe the sounds made by the constriction of the artery in 1905.
Similar articles
-
From Concept to Cure: The Life and Legacy of Scipione Riva-Rocci.Cureus. 2024 Sep 29;16(9):e70436. doi: 10.7759/cureus.70436. eCollection 2024 Sep. Cureus. 2024. PMID: 39473675 Free PMC article. Review.
-
[Epistemological focus on sphygmomanometry].Rev Invest Clin. 2002 Jan-Feb;54(1):84-91. Rev Invest Clin. 2002. PMID: 11995412 Spanish.
-
Blood pressure measurement: lessons learned from our ancestors.Curr Pharm Des. 2015;21(6):700-4. doi: 10.2174/1381612820666141023163313. Curr Pharm Des. 2015. PMID: 25341864
-
[Riva-Rocci and blood pressure].Ned Tijdschr Geneeskd. 2013;157(3):A5536. Ned Tijdschr Geneeskd. 2013. PMID: 23328024 Dutch.
-
Demise of the mercury sphygmomanometer and the dawning of a new era in blood pressure measurement.Blood Press Monit. 2003 Feb;8(1):19-21. doi: 10.1097/01.mbp.0000057012.67622.de. Blood Press Monit. 2003. PMID: 12604931 Review.
Cited by
-
The doctor's bag in 1911.CMAJ. 2012 Jan 10;184(1):E100-2. doi: 10.1503/cmaj.111963. Epub 2011 Dec 19. CMAJ. 2012. PMID: 22184359 Free PMC article. No abstract available.
-
Intelligent Wearable Wrist Pulse Detection System Based on Piezoelectric Sensor Array.Sensors (Basel). 2023 Jan 11;23(2):835. doi: 10.3390/s23020835. Sensors (Basel). 2023. PMID: 36679632 Free PMC article.
-
Study on a Concentric Tube Bulb Manometer and its Performance Compared to U-shaped Manometer.Sensors (Basel). 2007 Nov 20;7(11):2835-2845. doi: 10.3390/s7112835. Sensors (Basel). 2007. PMID: 28903264 Free PMC article.
-
From Concept to Cure: The Life and Legacy of Scipione Riva-Rocci.Cureus. 2024 Sep 29;16(9):e70436. doi: 10.7759/cureus.70436. eCollection 2024 Sep. Cureus. 2024. PMID: 39473675 Free PMC article. Review.
-
Influence of ethnicity on acceptability of method of blood pressure monitoring: a cross-sectional study in primary care.Br J Gen Pract. 2016 Aug;66(649):e577-86. doi: 10.3399/bjgp16X685717. Epub 2016 Jun 6. Br J Gen Pract. 2016. PMID: 27266860 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical